B-005 Analytical Performance Evaluation of Two HbA1c Testing Methods on Roche cobas c513 Analyzers

Oct 2026 · Clinical Chemistry · 0 citations

Abstract

Hemoglobin A1c (HbA1c) is the primary marker for monitoring long term glycemic control, and harmonization across testing methods remains essential for clinical decision-making. Roche recently introduced the Tina quant® Hemoglobin A1cDx Gen. 4 (A1CX4) assay, a monoclonal antibody–based formulation that replaces the previous Gen. 3 polyclonal reagent (A1CX3) while maintaining an equivalent analytical principle. Given reported variability across HbA1c methods and the importance of meeting National Glycohemoglobin Standardization Program (NGSP) performance targets, this study evaluated the analytical performance of A1CX4 versus A1CX3 on cobas® c513 analyzers, including assessment of variance observed in NGSP survey results. Validation followed CLSI (EP05 A3, EP09 A3, EP15 A3, and EP17 A2) guidelines and utilized EP Evaluator® for data analysis. Precision studies included simple (n=80) and complex (n=240) analyses using Bio Rad controls. Accuracy was assessed using College of American Pathologists (CAP) and NGSP proficiency samples (n=15). Linearity was evaluated using commercial sets spanning 4.2–18.3% HbA1c. Method comparison (n=100) and between instrument comparison (n=20 across eight instruments) were performed. Total allowable error (TEa) was set at 6%, with one third allocated to random error and one third to systematic error. NGSP survey performance and variance were specifically examined to evaluate alignment with NGSP certification limits. Five samples with common hemoglobin variants were tested to assess potential hemoglobinopathies interference. Initial validation with A1CX4 showed unacceptable bias at low and high HbA1c concentrations, resulting in failure to meet accuracy goals and increased variance relative to NGSP target values. Collaboration with Roche led to revision of calibration setpoints, which significantly improved method accuracy and reduced NGSP survey variance. Following calibration adjustments, all analytical performance goals were met: imprecision =2%, accuracy =4% deviation, method and instrument comparison =4% difference, and linearity recovery within 2% across the analytical measuring range. Revised A1CX4 results demonstrated no clinically significant bias at medical decision thresholds and achieved consistency with NGSP target performance. No interference was observed for hemoglobin variants tested. Method comparison indicated performance comparable to established HbA1c testing approaches, supporting inter method harmonization. Initial verification of the Tina quant® Hemoglobin A1cDx Gen. 4 assay identified calibration related performance issues, highlighting the critical role of laboratory vendor collaboration during method implementation. Adjustment of calibration setpoints resolved the observed biases, yielding improved accuracy, acceptable NGSP survey variance, and compliance with NGSP and CAP performance specifications. The revised A1CX4 assay demonstrates strong precision, accuracy, linearity, and instrument to instrument comparability and is suitable for routine clinical use. Its performance aligns with expectations for standardized HbA1c testing and supports reliable use in diabetes diagnosis and management.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.