Skip to content

B-189 Comparative Analysis of Free Light Chain Assay and Electrophoretic Techniques in the Laboratory Assessment of Monoclonal Abnormalities

Oct 2026 · Clinical Chemistry · 0 citations

Abstract

Monoclonal gammopathies (MG) is a broad term encompassing several pathologies, including Multiple Myeloma (MM). Diagnosis relies on several factors including the detection of monoclonal protein (M protein) through serum protein electrophoresis (SPE) and serum immunofixation (IFE) tests in addition to free light chain (FLC) measurement according to the International Myeloma Working Group (IMWG). The aim of this study was to compare and stratify FLC measurements in relation to IFE and SPE data. Serum samples collected between February and October of 2025 were selected based on the absence of a monoclonal spike on SPE test, regardless of the IFE outcome. All samples were analyzed by FLC assay using the Optilite® instrument (The Binding Site Group Limited, Birmingham, UK) with the Freelite® Kappa Free and Lambda Free reagent kits. Demographic variables (age and sex) and laboratory parameters were evaluated. Reference intervals applied were: kappa/lambda ratio, 0.26–1.65; kappa, 3.30–19.40 mg/L; and lambda, 5.71–26.30 mg/L. A total of 1,858 cases were evaluated; 57.4% (1066/1858) were women and 30.4% (565/1858) were aged 61-70 years. Overall, 68.5% of the total was older than 60 years. On IFE analysis, 14.4% (267) showed the presence of both light and heavy chains, 1.1% (21) heavy chains, 1% (18) only light chains, and 83.5% (1552) negative results. Among FLC results, 71.5% (1329) had kappa/lambda ratios within the reference range, whereas 28.5% (529) were abnormal, with kappa predominance in 90% and lambda in10%. The comparison between IFE and FLC showed agreement in 64.4% (1197) negative results and 8.2% (153) positive results. Regarding the discordant results, 20.2% (376) presented an altered kappa/lambda ratio without light chain detection on IFE, whereas 7.1% (132) exhibited detectable light chains on IFE despite a normal kappa/lambda ratio in FLC. Among the 1573 samples without detectable light chain on IFE, 76.1% (1197) had a normal kappa/lambda ratio, 1.5% (23) a ratio < 0.26 and 22.5% (353) a ratio > 1.65 in FLC. Of 1,329 samples with normal kappa/lambda ratio, 269 had kappa and lambda results within reference value, 687 showed increased kappa and lambda levels, two showed decreased of both chains, and 371 displayed mixed alterations (isolated increases or decreases in kappa or lambda) without affecting kappa/lambda ratio. Such isolated kappa and lambda abnormalities in the presence of a normal ratio may reflect non-monoclonal clinical conditions. This study highlights the importance of FLC testing as a complementary tool in the evaluation of monoclonal abnormalities, particularly in patients without a monoclonal spike in the SPE or light chain on IFE. Abnormalities identified exclusively by FLC testing support their role in the early detection of light chain-related disorders and in risk stratification, enabling more accurate and targeted clinical follow-up. A further advantage is analyzing kappa and lambda separately, especially when the kappa/lambda ratio is normal. Our findings highlight the contribution of FLC measurement in enhancing the sensitivity of laboratory diagnostics for monoclonal conditions.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.