Skip to content
Open access

Comparison of bilateral sagittal split osteotomy fixation using bicortical screws versus miniplates in orthognathic surgery: A retrospective study of 126 patients.

Nov 2026 · Journal of Stomatology Oral and Maxillofacial Surgery · pp. 103083 · 0 citations · 15 references
Medicine

Abstract

Background

Bilateral sagittal split osteotomy (BSSO) is the standard procedure for mandibular repositioning. The choice of fixation technique, particularly between bicortical screws and miniplates, remains debated. These techniques may influence key postoperative outcomes such as skeletal stability, neurosensory complications, temporomandibular joint (TMJ) function, and patient satisfaction.

Methods

This retrospective multicenter study was conducted across three French university hospitals and focuses on patients who underwent BSSO between January 2020 and May 2024. All surgeries were performed by one experienced surgeon following a standardized protocol. Patients were divided into two groups according to the fixation method: bicortical screws or miniplates. Clinical data and patient-reported outcomes were collected through medical records and postoperative questionnaires. These outcomes included skeletal relapse requiring revision surgery, labiomental sensory disturbances, TMJ symptoms, quality of life (evaluated by an adaptation of OHIP-14 / OQLQ), and osteosynthesis material perception.

Results

Our study included 126 patients (59 bicortical screw, 67 miniplate). Baseline characteristics were comparable. Skeletal relapse requiring surgical revision occurred in 8.5% of patients in the screw group and 13.4% in the miniplate group (p=0.37). Quality of life scores showed no significant difference (p=0.79). TMJ symptoms and hardware perception were similar. Persistent labiomental sensory disturbances were more frequently reported in the screw group (40.7% vs 28,4%), though not significant (p=0.15).

Conclusion

Bicortical screws and miniplates provided similar outcomes for skeletal stability, TMJ function, and quality of life. A non-significant trend toward fewer long-term sensory disturbances was observed in the miniplate group. These findings support the clinical equivalence of both technique in standardized conditions.