Abstract P1017: Quantifying Hemodynamic Responses to Epinephrine Administration During Cardiac Arrest
Abstract
Background: The 2025 AHA Pediatric Advanced Life Support guidelines recommend epinephrine every 3–5 minutes during cardiac arrest (Class IIb), yet supporting evidence remains limited and hemodynamic effects of repeated dosing are not well characterized. Epinephrine raises coronary perfusion pressure via α 1 -mediated vasoconstriction and a resulting rise in diastolic blood pressure, quantifiable by computing the pressure–time integral (PTI) of the arterial diastolic waveform. In preclinical models, PTI attenuates with subsequent doses, likely due to receptor desensitization and arrest progression. Whether this decay occurs in humans, and whether its magnitude predicts resuscitation failure, is unknown. Hypothesis: The hemodynamic response to epinephrine boluses, quantified as the PTI of arterial diastolic pressure, declines with repeated dosing during cardiac arrest, characterized by exponential decay constant k. Methods: A single-center retrospective cohort of pediatric cardiac ICU arrests (2024–2026) receiving ≥2 epinephrine doses with continuous invasive arterial monitoring were identified. For each bolus, the PTI of arterial DBP above a 30-second pre-bolus baseline was computed over the subsequent 2 minutes. An exponential decay model was fit across bolus number (ln [PTI] ~ –k х dose index) to estimate each patient's per-bolus decay. The primary outcome was failed conventional resuscitation (ECPR < 20 minutes or death). Results: Twenty-one arrests met inclusion criteria and contributed 137 epinephrine boluses. All arrests had a measurable positive PTI of the arterial DBP. Median first-dose PTI was 524 mmHg·s (IQR 291-1336) and decreased to median 172 mmHg·s (IQR 105-595) by dose 5. In 14 out of 21 arrests (67%), last dose PTI was lower than first dose. Across all arrests with at least two analyzable boluses (n=20), the per-patient decay constant did not differ significantly from zero (Wilcoxon, p=0.17). Thirteen arrests (65%) had a positive exponential decay (k > 0; median k 0.47 per dose, IQR 0.10–0.54) and seven arrests (35%) had k < 0 (median k –0.21 per dose, IQR –0.37 to –0.12), indicating no consistent dose-related attenuation. In exploratory comparisons, arrests with ROSC (n=6) had higher first-dose PTI than those with ECPR/death (n=15) (median 1444 vs 495 mmHg·s), though not significant (Mann-Whitney, p=0.095). Conclusions: In this pilot cohort of pediatric in-hospital arrests, PTI computation of invasive arterial monitoring was feasible and revealed substantial interindividual variability in hemodynamic responsiveness to epinephrine across boluses. Most patients showed attenuation of response with successive doses, but effect magnitude and decay kinetics varied widely. These findings support validation of PTI-based decay metrics in larger cohorts to assess whether kinetics can inform individual resuscitation strategy or timing of escalation to ECPR.