Coupled Electro-Thermal Simulation of a PCM-Cooled Supercapacitor Cell under a Realistic Bus Stop-Start Duty
Abstract
Supercapacitors are widely used in hybrid and electric vehicles to absorb regenerative-braking energy and supply acceleration peaks, but their performance and lifetime depend strongly on temperature under repeated high-current transients. Phase Change Materials (PCMs) offer passive cooling, yet many PCM-based studies simplify the heat source as a constant cycle-averaged power input, which may not represent realistic stop-start driving. This study develops a coupled electro-thermal simulation framework for a PCM-cooled Maxwell BCAP3000 cell under an urban bus duty cycle at 40 °C ambient temperature. Heat generation is computed dynamically from an equivalent-circuit model with temperature-dependent ESR and coupled to a thermal model of an RT42 PCM jacket. Three cases are compared: natural convection without PCM, PCM cooling with constant-power heating, and PCM cooling with full dynamic coupling. PCM cooling reduces the peak cell temperature from 64.4 °C to approximately 45.8 °C. The constant-power assumption captures the bulk temperature and PCM utilization but significantly underpredicts short-term fluctuations driven by acceleration and braking pulses: 0.20 °C versus 1.25 °C in the baseline case. Across the parametric study, the dynamic model predicts ripples 1.7 to 12.4 times larger than the constant-power model, confirming the need for full coupling in aging, PCM fatigue, and transient thermal-safety assessment.