Sep 2026· Advances in Structural Engineering· 0 citations· 21 references
Abstract
This paper presents an experimental and numerical investigation into the structural performance of thin-walled square concrete-filled steel tubular (CFST) columns stiffened with internal steel liners under axial compression, mainly focusing on performance optimization through rational steel allocation, enhanced constructability via tube discontinuity at the ends, and the exploration of corrugated liners and self-tapping screw connections. A total of 14 short column specimens were tested, including unstiffened, circular liner-stiffened (SC), and octagonal liner-stiffened (SO) types. The results demonstrate that both liner types can significantly enhance the axial load-bearing capacity, ductility, and buckling resistance of thin-walled CFST; discontinuing the thinner tube at the column ends effectively addressed joint constructability with minimal compromise to performance. Finite element models are developed to investigate the bearing mechanism. The results of parametric analysis indicate that the liner-to-tube steel allocation ratio (
γ
) critically influences optimal performance. Finally, the method for predicting axial resistance proposed in the previous study was modified to adapt to a wider range of parameters, showing excellent agreement with experimental and numerical results.
To address insufficient lateral restraint and the susceptibility of the flat walls of traditional concrete-filled steel tubular (CFST) rectangular flat columns, a built-up rectangular CFST flat column with integrated longitudinal cold-formed stiffening ribs is proposed. The FE model was validated against the global res...
Corrugated steel plate walls (CSPWs) are extensively utilized as high-performance, lightweight, and ductile lateral load-resisting elements in prefabricated steel structures. However, premature out-of-plane buckling compromises their lateral load-bearing capacity and energy dissipation performance, which poses a crit...
Li-Fei Feng, Gui-Rui Lin, Chao Yang et al.· Journal of Structural Engine...· 0 citations
Concrete-filled steel tubular (CFST) columns are widely used in high-rise and long-span structures due to their high strength, stiffness, and ductility. However, conventional CFST column–reinforced concrete (RC) beam connections usually involve complex detailing, column capacity reduction, and inefficient construction....
Bo Zha, Shi-Chun Zhang· Scientific Reports· 0 citations
The strengthening of intermediate-length concrete-filled steel tubular (CFST) columns using CFRP has attracted growing attention, but the effect of fibre orientation on the axial compressive behaviour—particularly for members where stability rather than strength governs—has not been fully clarified. This study therefor...
Zhe-Ming Wen, Qi Liu, Cheng-Gao Li et al.· Buildings· 0 citations
To improve the mechanical performance of large-size concrete-filled steel tubes without increasing the steel consumption, this study conducted a numerical analysis of the flexural behavior of concrete-filled square steel tubes with embedded steel angles and spiral stirrups (CFSST-SASS). A finite element (FE) model was...
To address the demands of green and sustainable development and to overcome the limitations of traditional concrete-filled double-skin tubular (CFDST) columns in terms of material efficiency and durability, this paper proposes a novel CFDST column with built-in ultra-high performance concrete (UHPC). Using the finite e...
Fei-Yu Shi, Wei Xu· International Conference on...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.