Skip to content
Open access

Structural assessment of a coastal reinforced concrete hotel using Schmidt rebound hammer testing

Oct 2026 · Proceedings of 5th Valencia International Biennial of Research in Architecture. Indoor-outdoor · 0 citations

Abstract

Reinforced concrete buildings located in coastal environments are exposed to aggressive durability conditions associated with high humidity, marine aerosols, intense rainfall and stable temperatures typical of tropical climates. Under these conditions, deterioration mechanisms such as chloride ingress, reinforcement corrosion and degradation of concrete cover may develop rapidly, particularly when construction defects or insufficient protective detailing are present.This paper presents the preliminary structural assessment of the Hotel complex, a reinforced concrete development located on the north-west coast of Dominica in the Caribbean. The complex, completed in 2017 but never commissioned, has remained exposed for several years to tropical marine conditions without maintenance. The investigation forms part of a broader inspection program designed to evaluate the structural condition of the building and support future rehabilitation decisions.Within this program, Schmidt rebound hammer testing was used as a first-stage non-destructive method to evaluate the homogeneity and estimated compressive strength of the concrete in the superstructure. Tests were carried out on columns, beams and slabs across several buildings within the complex. The estimated compressive strength values ranged between 17.8 MPa and 36.6 MPa, indicating moderate variability in concrete quality.Visual inspection of the structure also revealed significant constructive deficiencies, particularly insufficient reinforcement cover in several structural elements, locally estimated at approximately 5 mm. Considering that durability provisions for reinforced concrete structures exposed to marine environments typically require cover values on the order of 40–50 mm, this condition represents a critical durability concern.The investigation suggests that rebound hammer testing can provide a useful preliminary indication of concrete quality in large existing structures, particularly in remote environments where access to advanced testing equipment may be limited. At the same time, the case highlights the importance of combining non-destructive testing with detailed pathology inspection when evaluating reinforced concrete buildings exposed to aggressive coastal environments.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.