Observation and analysis of two-phase flow behaviour at exit of turbopump inducer with CO2-dissolved water
Abstract
In the present study, we conducted a visual observation of two-phase flow behaviours at the inlet and the outlet of inducer, and we conducted an image analysis to discuss the difference. A three-bladed inducer was employed as a test pump, and water with carbon dioxide (CO2) was used as working fluid to highlight the effects of dissolved gases on pump performance. Two-phase inflow was realized through the precipitation of CO2 in low pressure region at the inlet of inducer, and the high-speed recording was conducted in inducer exit region with measuring the performance parameters. As inlet pressure was decreased, we observed the gradual increase of gas-liquid volume flow rate ratio at the inlet, but the appearance of gas phase at the outlet was clearly delayed to the lower pressure condition, suggesting the occurrence of redissolution through the pressurization by the inducer. To explain this phenomenon, we conducted a bubble dynamics analysis against a spherical bubble flowing through the inducer with pressurization. Rayleigh equation and the mass conservation of CO2 in the bubble considering the gas diffusion across the bubble surface were simultaneously solved. Given the increased diffusion coefficient assuming the turbulent diffusion, we could reproduce the dissolution effect well.