Abstract 19102: Diagnostic Performance of AI-Enabled ECG Across Standard, Reduced-Lead, and Portable ECG Platforms for Detection of Left Ventricular Systolic Dysfunction: A Systematic Review and Meta-Analysis

Nov 2026 · Circulation · 0 citations

Abstract

Background: Artificial intelligence-enabled electrocardiography (AI-ECG) can identify left ventricular systolic dysfunction (LVSD), but whether diagnostic performance is maintained with reduced-lead and portable ECG acquisition remains uncertain. We performed a systematic review and meta-analysis to evaluate AI-ECG performance across ECG platforms and explore sources of heterogeneity. Methods: This PROSPERO-registered systematic review and meta-analysis followed PRISMA-DTA recommendations. PubMed, Embase, Web of Science, and Google Scholar were searched from January 2016 to March 2026. Studies evaluating AI-ECG against echocardiographically confirmed LVSD were included. Diagnostic accuracy was synthesized using a bivariate random-effects (Reitsma) model. Prespecified subgroup analyses examined ECG platform, validation strategy, study design, LVSD definition, and study quality. Risk of bias was assessed using QUADAS-2. Results: Among 31 studies comprising 47,177 participants met inclusion criteria. Twenty studies contributed diagnostic 2х2 data for meta-analysis, including 12 standard 12-lead, 5 portable single-lead, and 3 reduced-lead studies. Pooled sensitivity and specificity were 81.2% (95% CI, 72.3-87.9%) and 85.9% (95% CI, 78.3-91.3%) for standard 12-lead AI-ECG, 81.4% (95% CI, 72.5-86.9%) and 75.5% (95% CI, 69.9-80.6%) for single-lead platforms, and 90.0% (95% CI, 84.9-93.6%) and 72.9% (95% CI, 32.5-93.8%) for reduced-lead platforms. Diagnostic performance was lower in externally validated and prospective cohorts. Sensitivity analyses yielded similar findings across standard (LVEF ≤40%) and non-standard LVSD definitions. Conclusions: AI-ECG demonstrates favorable diagnostic performance for LVSD detection across standard, reduced-lead, and portable ECG platforms. Available studies suggest that diagnostic performance may be preserved following ECG lead reduction, although supporting data remain limited. Validation strategy and study design appear to contribute to performance variability. Interpretation of reduced-lead findings is constrained by the small number of available studies and substantial heterogeneity across populations, LVSD definitions, and AI architectures. Standardized LVSD definitions, independent external validation, and direct platform-comparative studies are needed to clarify the role of reduced-lead and portable AI-ECG screening strategies.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.