Tracking the misshapen: intermittent hemodynamic measurements miss parkinsonian orthostatic instability—a pilot study
Abstract
Background: Orthostatic hypotension (OH) in Parkinson’s disease (PD) is traditionally screened using bedside intermittent blood pressure (BP) measurements at determined timings after standing. However, transient BP fluctuations remain clinically undetected due to the low sampling rate. Objective: To compare intermittent (standard-of-care) versus continuous beat-to-beat BP monitoring during orthostatic challenge in a medicated PD patient, evaluating feasibility and sensitivity for detecting transient hemodynamic events and non-linear BP trajectories. Methods: A single medicated PD patient (ON state) underwent an extended active standing test, with simultaneous beat-to-beat BP monitoring via validated finger photoplethysmography. Systolic BP (SBP) was analyzed at standard protocol time points (recumbent baseline; 1, 3, 5, 8, and 10 minutes post-standing) and continuously. Outcomes included SBP nadir, maximum SBP, beat-to-beat variability (coefficient of variation, CV), and cumulative hypotensive burden area under the curve (AUC). Agreement between methods was assessed using Bland-Altman analysis. Results: The recumbent SBP baseline averaged 124 mmHg (SD = 3 mmHg). Intermittent sampling identified a nadir of 117 mmHg at 3 minutes post-standing (−7 mmHg; −5.5% compared to the recumbent baseline), below the classical OH threshold, with an AUC of 593.7 mmHg·s. Continuous monitoring revealed a true nadir of 108 mmHg at 110s (−16 mmHg; −13%), occurring 70s earlier, and exhibited non-linear triphasic dynamics: an initial compensatory rise (0–15 s; R²=0.38), a gradual decline (15–60 s; R²=0.04), followed by a gradual increase reaching a late hypertensive overshoot (151 mmHg at 586s). Beat-to-beat CV was 7% (SD=9 mmHg). Continuous AUC measured 1,567 mmHg·s, with 33% of beats below baseline. Bland-Altman analysis demonstrated that intermittent sampling mistracked nadir SBP by +9 mmHg (+8%), underestimated hypotensive drop by −57%, and underestimated cumulative burden by −62% (all p<0.05). Conclusion: Standard-of-care intermittent measurements demonstrated significant deviations from continuous physiological dynamics. Beat-to-beat BP monitoring enables detection of transient events that are missed by intermittent assessments. To precisely quantify the magnitude of these discrepancies and to develop strategies to enhance the sensitivity of intermittent measurements in settings lacking continuous monitoring, studies involving larger cohorts are warranted.