Skip to content

Abstract P1049: Non-Invasive Abdominal Aortic Occlusion with a Circumferential Pneumatic Band Reduces Blood Loss in Porcine Femoral Hemorrhage

Nov 2026 · Circulation · 0 citations

Abstract

Background: Traumatic hemorrhage due to non-compressible torso or junctional hemorrhage remains difficult to treat, especially in prehospital settings. Recent development of Abdominal Aortic and Junctional Tourniquet devices have provided an option to control abdominal or femoral hemorrhage. They are not widely available in prehospital settings. Thus, there remains an urgent need for a rapid, non-invasive, medic-deployable method to temporarily occlude the abdominal aorta and reduce ongoing hemorrhage in prehospital settings. We have developed a thoracoabdominal CPR system that incorporates a circumferential abdominal pneumatic band. Objective: We tested whether the abdominal component of a thoracoabdominal circumferential CPR device could function as an effective non-invasive abdominal tourniquet to reduce femoral blood loss in a porcine model. Methods: Following a CPR study in an instrumented 35 kg Yorkshire swine, mean arterial pressure was stabilized (60-80 mmHg) with fluid administration. After administration of heparin (5000 units), a 6F femoral catheter (1.8mm Inner Diameter, 14cm length) was used to induce controlled bleeding. Blood loss was measured over 10-second intervals with the abdominal band either deflated (control) or inflated to 4.0 PSI. Trials were performed in pseudo-randomized order (alternating blocks of control and band conditions). Six trials were completed in each condition. This was a single-animal pilot study. Results: Inflation of the abdominal band to 4.0 PSI resulted in near-complete cessation of blood loss (Figure 1) (M+_SD, 0.17 ± 0.17 cc per 10-second bleed). In contrast, control trials without band inflation produced substantial ongoing hemorrhage (6.67 ± 1.37 cc per 10-second bleed; p < 0.01). Conclusions: In this preliminary single-animal study, a circumferential abdominal pneumatic band, when used as a non-invasive tourniquet at 4.0 PSI, was associated with reduced blood loss from a femoral arterial source in a porcine model. These findings support further investigation of this technology as a rapid, medic-applicable intervention for non-compressible torso and junctional hemorrhage. Additional animal studies are indicated and ongoing.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.