Seismic Performance of RC Frame Structures with Masonry Infill Walls Strengthened by Mortar Surface Layers

Oct 2026 · Materials · Vol 19, pp. 4531 · 0 citations · 31 references
Medicine

Abstract

Although infill masonry walls in frame structures are classified as non-structural components, they can still resist a portion of seismic forces during earthquakes. Historical earthquake damage indicates that infill masonry walls in frame structures often act as the first seismic defense line and fail first, thereby mitigating or delaying damage to the main frame to a certain extent. Such damage cases are frequently observed. Therefore, it is necessary to investigate the enhancement of the seismic performance of the main structure contributed by infill masonry walls, and further to study the effect of infill-wall retrofitting on the seismic behavior of frame structures. The mortar surface reinforcement method, owing to its convenient construction and low cost, is one of the commonly used techniques for enhancing the seismic performance of masonry walls. This paper conducts finite element analysis on a frame structure located in a seismic fortification zone of intensity 8. The seismic performance of a bare frame, a frame with infill masonry walls, and frames with mortar surface reinforcement applied to infill walls at different locations are compared. Parameters including inter-story drift ratio, floor seismic forces, column shear forces, and load–displacement responses under various earthquake actions are analyzed. The results demonstrate that, for the numerical model employing an idealized interface assumption, the presence of infill walls significantly reduces the inter-story drift and column shear forces of the frame structure. Compared with the unretrofitted model, the seismic bearing capacity of the frame structure with mortar-reinforced infill walls increases by 18.57–36.19%. Among the different retrofitting schemes, the case with vertical and horizontal reinforcement applied to half of the wall area each achieves similar inter-story drift control as other schemes, while simultaneously reducing the floor seismic forces and the shear forces carried by frame columns. Thus, partial reinforcement of infill walls is recommended in structural retrofitting design, accompanied by experimental validation to quantitatively assess the retrofitting efficacy whenever possible. The findings of this study can serve as a reference for improving the seismic bearing capacity of frame structures through the mortar surface reinforcement method applied to infill masonry walls.

Read PDF

Similar papers

Oct 2026

In-plane seismic performance of different ductile masonry infill systems for resilient RC buildings

Masonry infilled reinforced concrete (RC) frames constitute a large portion of the global building stock. Although masonry infills are commonly treated as non-structural elements in seismic design, extensive experimental evidence and post-earthquake observations have demonstrated their significant influence on the stru...

P. Morandi, R. Milanesi, M. Preti et al. · 0 citations
Open access 2026

Seismic response assessment of RC frame buildings with masonry infill openings and soft story irregularity under dynamic soil–structure interaction

Masonry infill walls are widely used in reinforced concrete (RC) buildings, but their seismic behavior is often studied using fixed-base models without fully considering soil–structure interaction. This study investigates the seismic response of a ten-story, one-bay RC frame with 0%, 30%, and 50% infill openings, with...

B. R. Shilpa, G. Narayana, B. Narendra · 0 citations
Open access 2026

Height-dependent seismic performance of reinforced concrete buildings in Portoviejo: A comparative study on the influence of masonry infill walls and staircases

The seismic response of reinforced concrete buildings can be significantly affected by masonry infill walls and staircases, which are often not explicitly considered in analytical models. This study evaluates the effect of these components on typical buildings in Portoviejo, Ecuador, to identify their influence on stru...

María Belén Mera, Brian Cagua Gómez · 0 citations
Open access Nov 2026

SEISMIC FRAGILITY OF INFILLED STEEL BUILDINGS WITH CHEVRON AND X-BRACED CONFIGURATIONS

The use of bracing frames to resist lateral forces in high seismic regions is essential, as earthquakes can cause severe structural damage and loss of life. This study investigates the interaction between chevron and X-braced steel frames and infill walls, focusing on their seismic fragility. The main objective is to d...

M. M. H. Al-Amrani, Salihi Salihi Abdu, Mohammadreza Vafaei et al. · 0 citations
Sep 2026

Seismic Performance of RC Frames with Assembled Energy-Dissipating Infill Walls Using Hollow T-Shaped Metal Connectors

In reinforced concrete (RC) frames, appropriate infill-wall connections can mitigate detrimental frame-wall interaction and improve seismic response. This study proposes an RC frame with an assembled energy-dissipating infill wall (RCF-AEIW) using hollow T-shaped metal connectors. The system largely retains the layout,...

Lin Chen, Yu Gao, Ming-Li Shi et al. · 0 citations
Review Open access Oct 2026

Seismic performance of reinforced concrete buildings with shear walls under structural irregularities

Structural irregularities can significantly alter the seismic response of reinforced concrete buildings by modifying stiffness, mass distribution and load paths. This study evaluates the influence of structural irregularities and shear wall placement on the seismic performance of mid-rise reinforced concrete buildings...

S. Nirushan, H. Damruwan, C. Lewangamage · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.