Abstract
INTRODUCTION Whether technology, alignment philosophy, or balancing strategy yields superior patient-reported outcome measures (PROMs) after total knee arthroplasty (TKA) remains uncertain. This study compared one-year PROMs across five technique pathways.
Methods
From a single-institution PROM database, 1,239 TKAs were grouped as computer-navigated measured-resection mechanical alignment (CN-MR-MA; n = 394), computer-navigated gap-balanced mechanical alignment (CN-GB-MA; n = 365), robotic functional alignment (R-FA; n = 246), robotic unrestricted kinematic alignment (RU-KA; n = 113), or robotic restricted kinematic alignment (RR-KA; n = 121). Each cohort represented one surgeon; navigated cohorts used posterior-stabilized and robotic cohorts with cruciate-retaining implants. The primary outcome was one-year Forgotten Joint Score-12 (FJS-12). Multivariable analyses adjusted for baseline PROM score.
Results
After baseline adjustment, FJS-12 differed significantly across cohorts (P = 0.004), with adjusted means from 39.7 (CN-GB-MA) to 58.0 (RR-KA). Only RR-KA versus CN-GB-MA remained significant after Holm correction (adjusted difference, 18.2 points; 95% confidence interval [CI], 8.4 to 28.1; P = 0.003), exceeding the 16.6-point minimal clinically important difference (MCID), although the interval included smaller values. The Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) differed on omnibus testing (adjusted P = 0.022) without a significant pairwise contrast. The Patient-Reported Outcomes Measurement Information System (PROMIS) Global Health and Veterans RAND-12 (VR-12) scores did not differ. Attainment of the FJS-12 patient-acceptable symptom state was similar across cohorts (72.8 to 82.9%; Holm-adjusted P = 0.902). Expectation fulfillment ranged from 75.6 to 90.5% and patient-reported additional surgery from 0.9 to 5.5%.
Conclusion
The joint-specific PROMs differed across pathways, with RR-KA exceeding CN-GB-MA on FJS-12 beyond the MCID, whereas generic measures and threshold attainment were comparable. Because each pathway bundled one surgeon, platform, implant, and philosophy, and no demographic covariates were available, these differences cannot be attributed to alignment strategy. Prospective, covariate-adjusted comparison is required.