Three-level neutral-point-clamped (NPC) inverters are widely used in medium- and high-power drives and grid-connected applications due to their reduced device voltage stress, improved output power quality, and lower switching losses relative to conventional two-level topologies. Among the potential failure modes, clamping diode open-circuit faults are difficult to detect because the clamping diodes conduct only during the zero-voltage states, and their failure produces only subtle distortions in the phase current waveform. This paper proposes a fault diagnosis method for clamping diode open-circuit faults in three-level NPC inverters. The method is based on a current asymmetry index defined as the ratio of the per-cycle mean phase current to the per-cycle mean absolute phase current. During healthy operation, this index is approximately zero in all phases. A fault causes the index to deviate markedly from zero, while the polarity of this deviation identifies the failed diode. The method requires only phase-current measurements already available in the inverter control system. Consequently, no additional sensors, hardware modifications, or changes to inverter operation are required. Simulation results obtained for a 10 kW three-level NPC inverter demonstrate successful fault detection within approximately one to two fundamental cycles for open-circuit failures of both the upper and lower clamping diodes in all three phases.
In recent years, high penetrations of inverter-based resources are posing significant challenges to the medium-voltage networks, in which protection schemes based on high fault currents and unidirectional power flow may not perform as expected. This paper proposes a dynamic fault-detection and relay-coordination scheme...
Muhammad Abdul Rauf, Munira Batool, I. Madni· Energies· 0 citations
Low-voltage DC–DC converters (LDCs) require high availability to prevent critical vehicle accidents caused by abrupt voltage drops resulting from switch faults. Therefore, rapid fault detection and technologies that ensure safe operation during fault conditions are essential. This paper proposes a fault-leg identificat...
Jin-Su Jang, Tae-Hyeon Lim, Seung-Hyeon Cho et al.· IEEE Access· 0 citations
A transformerless switched-capacitor-based multilevel inverter (TLSCMLI) has emerged as an optimistic substitute for traditional inverters due to reduced component counts, self-voltage balancing, inherent voltage-boosting capability, removal of bulky magnetic components, and the compact size of the photovoltaic (PV) in...
Accurate and low-cost fault diagnosis is essential for improving the reliability of cascaded neutral-point-clamped (NPC) inverters. This paper proposes a single-sensor fault diagnosis method for a single-phase three-module cascaded NPC inverter. Only one DC-side current sensor is required for the diagnostic algorithm,...
Chao Wu, Yi-Hao Wang, Pengcheng Han et al.· Machines· 0 citations
Abstract This manuscript proposes a single-phase hybrid fault-tolerant seven-level inverter for grid-connected applications. In conventional multilevel inverters, a fault in any switching device can adversely affect the output voltage levels, making the inverter unsuitable for reliable grid integration. Therefore, inco...
J. Rajesh, K. Suresh, Suchana Mishra et al.· International Journal of Eme...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.