Skip to content
Open access

Taylor-free exact-trigonometric dynamic modeling and PSO-tuned adaptive super-twisting control of a two-section spatial continuum robot: a simulation study

Nov 2026 · Frontiers in Robotics and AI · 0 citations · 39 references

Abstract

Cable-driven continuum robots are difficult to model and control because of their strongly coupled spatial deformation and configuration-dependent tendon actuation. This simulation study develops a control-oriented dynamic model of a two-section spatial continuum robot in which the piecewise-constant-curvature geometry is evaluated with exact sine and cosine functions instead of Taylor polynomials; the Jacobians and inertia derivatives of this exact geometry are computed by central finite differences, whose relative error was verified to be below 1 0 − 9 against complex-step derivatives. The generalized coordinates q = [ θ 1 , ϕ 1 , θ 2 , ϕ 2 ] T let both bending angles and bending-plane orientations evolve dynamically. A particle-swarm-optimization-tuned adaptive super-twisting sliding-mode controller (PSO-ASTSMC) is proposed, and a strict Lyapunov function establishes finite-time convergence of its sliding variables for perturbations whose rate satisfies a computable linear-matrix-inequality bound. In simulation, PSO-ASTSMC ranked first among six controllers (PID, computed-torque PD, SMC, fast terminal SMC, and fixed-gain STSMC) on the two tuning trajectories (joint/Cartesian RMSE 1.628 ° /14.328 mm and 1.918 ° /13.631 mm) and on two trajectories not used for tuning, reducing the Cartesian RMSE by 27%–51% at comparable RMS effort; twenty independent PSO runs reproduced this result (coefficient of variation ≤ 1.5 % ). Compared with a second-order Taylor-expanded model, the exact geometry removed about 20 mm of open-loop prediction error at no computational cost. A robustness analysis showed that, with gains tuned on the nominal model, all six controllers fail when the stiffness or damping of the robot differs from the model by about 10%, because the generalized inertia of the robot is small. After a common uncertainty-aware retuning, PSO-ASTSMC was the only controller without failures over 40 random plants with ± 15 % stiffness and damping errors (median post-transient tip error 0.59 mm), at the cost of a 500-Hz control loop and a control signal that is sensitive to measurement noise. Disturbance tests with section-wise forces, tendon follower forces, and repeated pulses showed complete tip recovery when sufficient time was available. All results are numerical: the reported margins are simulated and require experimental confirmation.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.