Skip to content
Open access

Agreement and reproducibility of intraoral scan- versus CBCT-based three-dimensional implant position assessment in the posterior mandible — a paired in vitro method-comparison study

Oct 2026 · International Journal of Implant Dentistry · Vol 12 · 0 citations · 38 references
Medicine

Abstract

Three-dimensional postoperative implant assessment is increasingly performed using intraoral scan (IOS) superimposition as a radiation-free alternative to cone-beam computed tomography (CBCT). However, it remains unclear to what extent IOS- and CBCT-based measurements agree and how reproducibility changes across posterior mandibular configurations. In this paired in vitro method-comparison study, based on the experimental platform of a previous study, 60 implants placed at Fédération Dentaire Internationale (FDI) positions 35, 36, 45, 46 and 47 in bounded edentulous spaces (BES) and distal extension situations (DE) underwent three IOS-based and three CBCT-based postoperative assessments relative to the virtual plan using the Treatment Evaluation Tool of the planning software. Angular, mesiodistal, buccolingual, apico-coronal, and three-dimensional (3D) deviations at implant base and apex were recorded, resulting in 180 paired measurements. Agreement was assessed by Bland-Altman analysis, and within-method reproducibility by the within-implant standard deviation (Sw). IOS variability was additionally separated into within-scan and between-scan components. Non-parametric analyses were used for comparisons by indication and FDI position. Mean absolute IOS–CBCT differences were 0.73° ± 0.55° for angular deviation, 0.22 ± 0.20 mm for the 3D base offset and 0.26 ± 0.22 mm for the 3D apical offset. Bland-Altman bias (CBCT − IOS) was small (− 0.35°; −0.05 mm; −0.07 mm) with 95% limits of agreement of [− 2.01°; +1.31°], [− 0.62; +0.53] mm and [− 0.73; +0.58] mm. Within-method reproducibility was superior for IOS in 8 of 9 parameters (e.g., Sw 0.20° vs. 0.55° for the angle), and IOS variability was dominated by scan-to-scan rather than within-scan re-evaluation. Discrepancies were larger in DE than in BES sites in 7 of 9 parameters (all p < 0.001 for the principal apical and buccolingual components) and were larger at position 47 than at position 35 (3D base p = 0.004; 3D apex p = 0.011). In this in vitro setting, IOS- and CBCT-based implant assessment in the posterior mandible showed good agreement with small overall differences, and IOS demonstrated lower within-method variability than CBCT. IOS-based superimposition may therefore serve as a radiation-free complement to CBCT for the postoperative evaluation of single implants in bounded posterior sites. Agreement decreased in distal extension situations and at more distal positions; in these configurations, and whenever clinical decisions depend on sub-millimeter or sub-degree precision, CBCT remains the reference technique. Confirmation in vivo is required before routine clinical use.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.