Computer vision-derived gait-state tracking of acute treatment response in Parkinson’s disease: external and prospective validation
Abstract
Continuous, treatment-responsive measurement of motor state is an unmet need in Parkinson’s disease and a broad challenge for digital biomarkers: clinical gait scales are coarse and ordinal, and most digital measures are never validated beyond their derivation setting. We present a digital biomarker derived from full-mesh 3D human-pose reconstruction in standard monocular video, built from high-contrast within-patient treatment transitions and applied to out-of-sample patients. In a retrospective cohort (53 patients) it discriminated treatment states (cross-validated AUROC 0.88) and defined a continuous motor-state axis. Across six independent cohorts (266 subjects, 3,591 walks, eight sites, three continents) it showed consistent medication effects in the two medication-labelled cohorts and tracked clinical gait impairment in the four cohorts carrying clinical gait ratings; in a prospective cohort (21 patients) it preserved ordered transitions for medication and deep brain stimulation. On identical paired observations it was more responsive than the ordinal MDS-UPDRS Part III item 3.10 (standardized response mean 1.29 versus 0.83 internally, 0.92 versus 0.54 externally); its finer resolution also registered directional within-patient improvement more often, an advantage of measurement resolution that reaches parity once change is required to exceed the minimal detectable change, supporting a scalable, generalizable measurement tool. This graphic explains a computer-vision method for tracking acute treatment response in Parkinson’s disease using standard monocular video without specialized hardware. It shows three steps: first, a single camera records the same patient before and after therapy; second, a markerless full-mesh 3D pose is reconstructed frame-by-frame; third, a gait-state biomarker is derived, with Levodopa and deep brain stimulation moving patients up the biomarker axis from negative to positive values. Validation data indicate the method was tested across 3,591 walks from 266 subjects at 8 sites on 3 continents. The biomarker correlates negatively with clinical gait impairment scores, showing that higher clinical impairment corresponds to lower biomarker scores. The biomarker detects changes more often than clinical scores, with 100 percent internal and 84 percent external detection rates of within-patient improvement compared to 68 and 37 percent for clinical gait scores, respectively.