Real-time volumetric MRI-guided MLC tracking: A feasibility study

Oct 2026 · 0 citations · 1 references
Physics

TL;DR

This study presents a proof-of-concept MLC tracking system for dynamic adaptation of the radiation treatment based on the real-time target localization facilitated by MRSIGMA on a 1.5 T MR-Linac.

Abstract

Background and purpose: The MR SIGnature MAtching (MRSIGMA) was recently proposed as a real-time free-breathing 3D MR imaging technique with an imaging latency of 148 ms. It is a powerful tool for intrafractional motion monitoring for disease sites such as those in the abdominal region. This study presents a proof-of-concept MLC tracking system for dynamic adaptation of the radiation treatment based on the real-time target localization facilitated by MRSIGMA on a 1.5 T MR-Linac. Material and methods: An MLC tracking interface was developed for integration with MRSIGMA. The centroid position of a moving target was computed in real time by MRSIGMA, which was then processed by a predictive filter to account for imaging and MLC adjustment latencies. The MLC leaves were repositioned by rigid translation. To validate the MLC tracking process, a 10 cm circular field was delivered to a moving phantom for a series of sinusoidal motions and patient motion. A clinical pancreas SBRT plan was also delivered with the patient motion trace. Results: For the circular field, geometric errors of<1.8 mm and overall system latency of<125 ms were achieved for all motion traces. Compared to no tracking, MLC tracking remarkably improved the dosimetric accuracy for the circular field and the clinical pancreas plan, with an average Gamma passing rate increased from 87.1% to 99.9% based on a 3%/2mm criteria. Interpretation: A 3D MRI-guided MLC tracking technique was developed and validated on a clinical MR-Linac. Preliminary results demonstrated great dosimetric improvements with MLC tracking for treatments with moving targets.

View source

Similar papers

Oct 2026

DEVELOPMENT OF A NEW IMAGE REGISTRATION-BASED METHOD FOR TRACKING VERTEBRAL MOTION IN KINETIC SAGITTAL MRI

Investigation of the similarity space for the tested parameters indicated that MRI image artefact was the principle reason for similarity minima not corresponding to the correct registration, hence failure of gradient descent optimisation.

K. Brownhill, F. Mellor, C. Heales et al. · 0 citations
Review Open access Oct 2026

Retrospective log‐based quality assurance of real‐time MLC adaptation on a helical tomotherapy platform

Abstract Background Real‐time multileaf collimator (MLC) adaptation is available on some helical tomotherapy treatment units. However, these systems are not supplied with software that facilitates the retrospective review of adapted delivery data. Purpose This study used in‐house software to complete a retrospective re...

S. Crowe, T. Kairn · 0 citations
Review Nov 2026

Real-Time Intrafraction Motion Management in Magnetic Resonance Imaging-Guided Adaptive Radiotherapy and Its Impact on Treatment Precision

Background and Purpose: Intrafraction motion remains a principal source of geometric uncertainty in external beam radiotherapy. Magnetic resonance imaging-guided adaptive radiotherapy (MRgART) uses continuous soft-tissue visualization throughout beam delivery to directly manage this uncertainty. This review criticall...

Manar Salah, Ahmed Shawky, Eman Gamal et al. · 0 citations
Open access Nov 2026

Real-time Volumetric Imaging for Minimally-Invasive Thoracic Interventions: A Deformable Phantom Study

Objectives: This study aimed to evaluate the ability of VoxelMap, a deep learning framework for 3D respiratory motion estimation, to generate volumetric images in real-time from 2D projections acquired for two deformable lung phantoms on a clinical interventional C-arm angiography system. Materials and Methods: VoxelMa...

A. Lin, A. Biju, A. Goode et al. · 0 citations
Open access Oct 2026

A clinical evaluation of spiral 4DCT and intelligent 4DCT sequence scanning.

Accurate 4DCT imaging is essential for radiotherapy planning but is often degraded by breathing irregularities. Phantom studies show that intelligent four-dimensional computed tomography (Direct i4D) sequence scanning can significantly reduce artifacts related to breathing irregularity compared to traditional spiral 4D...

Yao Hao, J. Schiff, D. Hong et al. · 0 citations
Nov 2026

A Low-Cost MR-Compatible Pneumatic Motion Phantom for Magnetic Resonance Imaging

We describe the detailed design, construction, and testing of a simple, low-cost, open-source, exclusively pneumatic phantom for gated magnetic resonance imaging (MRI) studies of cyclic motion. The overall phantom cost is approximately $200. It is designed to use widely-available materials and an easy-to-program, adapt...

Jonathan B. Martin, M. Barron, Charlotte R. Sappo · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.