Skip to content
Open access

Ultra-High-Resolution Dual-Source Photon-Counting CT for Expanded Characterization of Pathophysiological Imaging Patterns in Multiple Myeloma.

Jul 2026 · Investigative Radiology · 0 citations · 54 references
Medicine

TL;DR

DS-PCCT identified a previously undescribed fat-attenuation-predominant imaging phenotype in MM that meets criteria for symptomatic bone disease but is not captured by current International Myeloma Working Group definitions of focal lesions.

Abstract

Rationale

AND

Objectives

Dual-source photon-counting CT (DS-PCCT) combines spectral imaging with ultra-high spatial resolution for whole-body assessment of multiple myeloma (MM). This study assessed axial and appendicular skeletal manifestations at initial diagnosis by exploiting attenuation characteristics of soft tissue and fat in low-keV virtual monoenergetic images (VMI).

Materials And Methods

In this retrospective study, 84 patients (67.1±10.5 y, 54 men) underwent whole-body DS-PCCT between November 2024 and December 2025. The sample comprised 53 therapy-naïve MM patients and 31 with precursor conditions (monoclonal gammopathy of undetermined significance, smoldering myeloma, solitary plasmacytoma). Three board-certified radiologists measured CT attenuation of osteolytic lesions and femoral bone marrow at 70 and 40 keV. Long bones were evaluated for diffuse high-grade, nodular, pseudonodular, and fatty marrow patterns, as well as endosteal scalloping.

Results

Among 53 MM patients, 40 (75.5%) spectral-morphologic analysis identified 3 patient-level imaging phenotypes of osteolytic bone disease: a soft-tissue-attenuation phenotype (n=25, 47.2%), a fat-attenuation phenotype (n=10, 18.9%), and coexistence of both lesion types (n=5, 9.4%). The pseudonodular pattern was the predominant femoral marrow imaging pattern, whereas fatty marrow (30.2%), nodular lesions (18.9%), and diffuse high-grade infiltration (3.8%) occurred less frequently. Endosteal scalloping occurred exclusively in osteolytic MM (18.9%). Precursor conditions mainly showed fatty (58.1%) and pseudonodular (38.7%) patterns. Low-keV VMI demonstrated distinct energy-dependent attenuation across patterns. Inter-reader agreement for Hounsfield unit measurements was good to excellent (ICC >0.82).

Conclusions

DS-PCCT identified a previously undescribed fat-attenuation-predominant imaging phenotype in MM that meets criteria for symptomatic bone disease but is not captured by current International Myeloma Working Group definitions of focal lesions. Spectral-morphologic characterization of marrow involvement may complement existing imaging criteria and aid differentiation between overt MM and nonspecific marrow abnormalities.

Read PDF

Similar papers

Open access Nov 2026

Ultra-High-Resolution Imaging of Rectal Cancer with Photon-Counting Detector Computed Tomography: An Exploratory Pilot Study on the Impact of Slice Thickness and Monoenergetic Reconstruction Level on Image Quality

Background/Objectives: To evaluate, in an exploratory pilot study, the influence of slice thickness and monoenergetic (ME) level on quantitative and qualitative image quality of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) in rectal cancer (RC). Methods: This prospective pilot study enrolled 21 pati...

A. Herold, A. Strassl, Daniela Beitzke et al. · 0 citations
Oct 2026

Low-dose vs standard-dose photon-counting CT for myopathy-associated interstitial lung disease: a prospective feasibility study.

LD PCCT serves as a radiation-sparing alternative for quantitative disease assessment, with total disease burden showing good agreement with the SD protocol, offering a radiation-sparing alternative without compromising CT-physiology correlation.

Zhen-Chen Zhu, Ke-Pei Xu, Yi-Yun Pang et al. · 0 citations
Nov 2026

Evaluation of Temporal Bone Image Quality with Low-Dose Photon-Counting CT in Cadaveric Heads.

BACKGROUND AND PURPOSE Photon-counting computed tomography (PCCT) is an emerging technology that offers improved spatial resolution and noise reduction at lower radiation doses than conventional CT; however, the effect of dose reduction on clinically significant image quality has not been well established. Following th...

Seong-Won Kim, Georgia R. R. S. S. Silva, Willem G. Calderon et al. · 0 citations
Review Open access Nov 2026

Iodine maps from photon-counting detector CT in thoracic imaging: a scoping review

Photon-counting detector CT (PCD-CT) acquires spectral data at every scan, enabling iodine map reconstruction without dedicated dual-energy protocols. This scoping review mapped the extent, characteristics, and findings of early clinical studies. Following the Joanna Briggs Institute framework and PRISMA-ScR reporting,...

A. M. Rendón-Garavito, I. E. Martínez Safar, Daniel A. Martínez D et al. · 0 citations