Optimizing Photon-counting CT for Congenital Heart Disease: The Value of Ultrasharp Kernels in Neonates and Infants.

Aug 2026 · Radiology: Cardiothoracic Imaging · Vol 8 4, pp. e250338 · 0 citations · 14 references
Medicine

TL;DR

KS and IR selection significantly affected image quality in pediatric cardiac photon-counting detector CT, with ultrasharp reconstruction providing the best quantitative and visual image quality for evaluation of complex coronary and structural heart anomalies.

Abstract

Purpose To evaluate the image quality of kernel sharpness (KS) and iterative reconstruction (IR) settings in high-pitch photon-counting detector CT for pediatric cardiac imaging. Materials and Methods This retrospective study analyzed photon-counting detector CT data from neonates and infants with congenital heart disease that were acquired between October 2022 and August 2023 at two specialized centers. Images were reconstructed using vascular kernels with varying KS (36, 40, 44, 48, 56, and 60) and IR levels (Q1-Q4) at a 1-mm section thickness. Visual image quality was assessed by one pediatric cardiologist and two radiologists using a five-point Likert scale, with selection of the most diagnostic reconstruction per patient. Image sharpness was quantified using edge rise distance, and signal-to-noise ratio and contrast-to-noise ratio were calculated. Statistical analysis used linear mixed models, with results reported as regression estimates with 95% CIs. Results A total of 47 patients (median age, 82 days [IQR, 4-227 days]; 28 male) were included. Subjective image quality improved with increasing KS (β = 0.07 Likert points per level; 95% CI: 0.06, 0.09) and IR level (β = 0.21 Likert points per level; 95% CI: 0.19, 0.23) (both P < .001). The most preferred reconstruction was a KS of 60 (ultrasharp kernel) with an IR of Q4 (highest IR level) (77 of 141 votes). Edge-rise distance decreased with increasing KS (-0.07 mm; 95% CI: -0.08, -0.06) and IR level (-0.06 mm; 95% CI: -0.06, -0.04) (both P < .001). Signal-to-noise ratio and contrast-to-noise ratio increased significantly with higher IR levels (both P < .001). Conclusion KS and IR selection significantly affected image quality in pediatric cardiac photon-counting detector CT, with ultrasharp reconstruction providing the best quantitative and visual image quality for evaluation of complex coronary and structural heart anomalies. Keywords: Pediatrics, CT-Photon Counting, Cardiac, Pediatric Cardiac Imaging, Congenital Heart Disease, Image Quality Optimization, Kernel Sharpness Supplemental material is available for this article. © RSNA, 2026.

View source

Similar papers

Open access Aug 2026

Plaque-Adapted Virtual Monoenergetic Image Selection for Carotid Plaque Visualization Using Photon-Counting CT

The findings support implementing standardized protocols with automatic dual-range reconstructions to enable efficient, individualized carotid plaque assessment in clinical practice and support implementing standardized protocols with automatic dual-range reconstructions for keV selection based on plaque composition.

Mirela Kostadinova, Lea B. Uebelacker, Tommaso D'Angelo et al. · 0 citations
Open access Aug 2026

Photon-counting CT iodine maps for late iodine enhancement: a retrospective feasibility study of image quality and reader confidence

Myocardial scar assessment is clinically relevant in advanced coronary artery disease, but late iodine enhancement (LIE) CT remains limited by image contrast and validation requirements. This study aimed to evaluate quantitative image quality and reader confidence of photon-counting detector computed tomography (PCD-CT...

V. Hartung, P. Gruschwitz, Julia Serfling et al. · 0 citations
Aug 2026

Clinical Photon-Counting CT in Neuroradiology: A Real-World Paired Comparison with Conventional Energy-Integrating CT.

BACKGROUND AND PURPOSE Photon-counting CT offers higher spatial resolution, improved contrast-to-noise efficiency, and spectral imaging, but its performance against heterogeneous EID-CT systems in routine use remains incompletely characterized. We compared image quality, pathology conspicuity, and radiation dose betwee...

Adrian Szum, Filip Moberg, Georgios Kalarakis et al. · 0 citations
Aug 2026

Assessment of image quality and feasibility of Photon-Counting detector CT for the Non-Contemporaneous follow-up of intracranial aneurysms treated with flow diverter stents.

PCD-CT provides superior stent lumen visualization compared to baseline imaging, while maintaining a sub-millisievert radiation dose, and represents a promising non-invasive surveillance tool, though prospective validation of its diagnostic accuracy for in-stent stenosis is required.

Jianghui Gao, Yang Bian, Rong-Ju Zhang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.