Permanent Magnet Synchronous Motor Maximum Torque per Ampere-Position Sensorless Control Based on High-Frequency Signal Injection
Abstract
This paper proposes a maximum torque-to-current ratio (MTPA) control method for the sensorless operation of permanent magnet synchronous motors (PMSM), which is based on the injection of a high-frequency signal. A virtual square-wave signal, which is superimposed on the reference current rather than physically injected into the motor windings, is used for MTPA tracking, while an actual sinusoidal high-frequency signal is injected for rotor position estimation. Processing the response signals generated within the motor enables distinct signals to be extracted for identifying both the MTPA control and the sensorless control. The MTPA is then achieved in sensorless control through respective high-frequency signal processing strategies. Simulation results validate the theoretical analysis and confirm the feasibility of the proposed method. Simulation results demonstrate that the proposed method can effectively achieve rotor-position estimation and MTPA operation under sensorless conditions. Stable position tracking and satisfactory dynamic performance are obtained throughout the operating process.