Supervised and Semi-Supervised UWB LOS/NLOS Classification in Industrial Environments
Abstract
Ultra-wideband (UWB) positioning systems are strongly affected by non-line-of-sight (NLOS) propagation, since obstructed ranges can introduce systematic positioning errors. Channel impulse response (CIR) measurements enable supervised LOS/NLOS classification, but verified labels are expensive to obtain for every new physical environment, whereas unlabeled CIR samples are naturally collected during deployment. This paper studies whether self-training can exploit such unlabeled UWB data without overstating generalization. We use a compact one-dimensional CNN and compare three protocols on an industrial UWB dataset collected at 18 locations, of which seven are labeled and eleven are unlabeled: a supervised seven-location baseline (SL-7), strict seven-location self-training (ST-7), and extended eighteen-location self-training (ST-18). SL-7 reaches 95.51% mean macro-F1 with 99.68% NLOS recall. ST-7 reaches the same mean macro-F1 at a confidence threshold of τ =0.90 and is therefore indistinguishable from SL-7, but changes the error balance by improving LOS recall while reducing NLOS recall. ST-18 does not improve over SL-7. These results show that standard high-confidence self-training is not reliably beneficial under physical location shift.