Abstract 15209: Late Obstructive Bioprosthetic Valve Thrombosis After Transcatheter Mitral Valve-in-Valve Implantation
Abstract
Background: Transcatheter mitral valve-in-valve implantation is an established option for degenerated surgical bioprostheses in patients at high surgical risk. Late bioprosthetic valve thrombosis is a potentially life-threatening complication, and the optimal treatment is not established. Case Presentation: A 71-year-old man with hypertension, dyslipidemia, prior coronary artery bypass grafting, paroxysmal atrial flutter, and a degenerated surgical mitral bioprosthesis underwent transfemoral transcatheter mitral valve-in-valve implantation with a 26-mm balloon-expandable prosthesis in September 2023. He was discharged in New York Heart Association (NYHA) class I on a vitamin K antagonist (warfarin; target international normalized ratio 2.0 to 3.0) and antiplatelet therapy. In October 2025, two years later, he developed exertional dyspnea (NYHA class II) despite a therapeutic target range. Echocardiography showed increased transprosthetic gradients and reduced leaflet mobility, and transesophageal echocardiography and cardiac computed tomography demonstrated hypoattenuated thrombotic material on the ventricular aspect of the leaflets with restricted motion, consistent with obstructive thrombosis. Management and Outcome: Anticoagulation was intensified (international normalized ratio 2.5 to 3.5) with continued antiplatelet therapy. After 60 days, symptoms progressed to NYHA class III with persistent obstruction (mean transprosthetic gradient of 9 mmHg, pressure half-time of 240 ms, effective orifice area of 0.9 cm 2 ). The Heart Team deemed reoperation prohibitive. Ultra-slow low-dose fibrinolysis with alteplase, 25 mg infused over 25 hours, was administered in a single cycle without bleeding or embolic complications. After treatment, the mean gradient fell to 4 mmHg, the pressure half-time to 120 ms, and the effective orifice area rose to 1.7 cm 2 , with restored leaflet mobility. Follow-up cardiac computed tomography confirmed complete thrombus resolution. Conclusion: To our knowledge, this is among the first reported cases of late obstructive thrombosis after transcatheter mitral valve-in-valve implantation in which complete resolution was confirmed by both transesophageal echocardiography and cardiac computed tomography after a single ultra-slow, low-dose alteplase cycle. In this patient at prohibitive operative risk, prolonged low-dose fibrinolysis reversed prosthetic obstruction without surgery, and cardiac computed tomography was useful for confirming the treatment response.