Effect of hybrid steel-polypropylene fiber content on concrete compressive and tensile strength
Abstract
Conventional concrete inherently possesses low tensile strength, limited strain capacity, and brittle failure behavior, which restricts its structural efficiency. To address these limitations, this experimental study systematically investigated the influence of hybrid fibers (steel and macro-polypropylene) on the compressive and splitting tensile strengths of concrete. Standard cylindrical specimens (150 mm χ 300 mm) were cast using commercial pre-packaged concrete (K-450 grade) with a constant superplasticizer dosage of 1%, followed by 28 days of water curing. Two hybrid volume fractions were evaluated: Hy 1.5% (1.0% steel + 0.5% polypropylene) and Hy 3.0% (2.0% steel + 1.0% polypropylene) and compared against a fiber-free control mix. Experimental results demonstrated significant improvements in mechanical performance corresponding to increased fiber dosages. Average compressive strength rose from 50.21 MPa (control) to 63.02 MPa (+25.52%) for Hy 1.5% and reached 70.30 MPa (+40.02%) for Hy 3.0%. Concurrently, splitting tensile strength increased sharply from 4.85 MPa to 10.34 MPa (+113.20%) and 12.15 MPa (+150.52%) for Hy 1.5% and Hy 3.0%, respectively, confirming the presence of a robust multi-scale crack-bridging mechanism. Although the 3.0% hybrid dosage yielded peak mechanical capacity, the 1.5% dosage offered mechanical performance benefits without matrix segregation, while also facilitating ease of workability.