Skip to content
Open access

Hybrid Funnel Technique Reduces Marginal Bone Loss Versus Conventional Drilling: A 3‐Year, Prospective, Non‐randomized, Controlled Clinical Trial

Jul 2026 · Clinical Implant Dentistry and Related Research · Vol 28 · 0 citations · 32 references
Medicine

TL;DR

HFT demonstrated superior preservation of marginal bone over 3 years, suggesting that reduction of cortical compression during osteotomy provides a biological advantage, and implant site preparation remains a key determinant of long‐term peri‐implant bone stability.

Abstract

ABSTRACT Purpose This study aimed to compare marginal bone loss (MBL) associated with Hybrid Funnel Technique (HFT) and conventional drill osteotomy for implant site preparation when bioactive implants are used, testing the null hypothesis that no significant differences occur at 1‐ and 3 years. Materials and Methods This prospective non‐randomized controlled clinical trial included patients undergoing implant rehabilitation with bioactive‐surface implants. Implants were placed using either conventional subtractive drilling (control group) or HFT (test group), which combines selective cortical preparation with medullary osteocompaction. The primary outcome was radiographic MBL at 3‐year follow‐up. Secondary outcomes included bleeding on probing (BoP) and plaque index (PI). Statistical analyses were performed at implant level, and linear mixed‐effects models were used to account for clustering within patients and adjust for potential confounders. Results A total of 87 implants in 43 patients were analyzed (42 control, 45 HFT). At 1‐year follow‐up, the test group reported significantly lower MBL (0.33 ± 0.43 mm vs. mean = 0.78 ± 0.82 mm; Mann–Whitney p‐value = 0.006). At 3 years, MBL was significantly higher in the conventional site preparation group compared with the HFT group (1.34 ± 0.79 mm vs. 0.46 ± 0.69 mm; p < 0.001). In multivariate mixed‐effects analysis, the implant site preparation technique was the only variable independently associated with MBL at 3 years (β = −1.10 mm, 95% CI = −1.675 to −0.527, p < 0.001), while insertion torque and other baseline variables showed no significant association. In addition, the HFT group demonstrated significantly lower BoP and PI scores, indicating more favorable peri‐implant soft tissue conditions. Conclusions Despite the use of identical bioactive‐surface implants, implant site preparation technique significantly influenced peri‐implant bone remodeling. HFT demonstrated superior preservation of marginal bone over 3 years, suggesting that reduction of cortical compression during osteotomy provides a biological advantage. Implant site preparation remains a key determinant of long‐term peri‐implant bone stability.

Read PDF

Similar papers

Open access Sep 2026

Bone dimensional stability with versus without a stent following apically repositioned flap and single-stage implant placement: a randomized clinical trial

Maintaining peri-implant bone and tissue health is essential for long-term implant success. The effectiveness of adjunctive stent stabilization is still unclear, though the apically repositioned flap (ARF) improves soft tissue conditions. Therefore, this study assessed whether the use of stents during single-stage plac...

Ahmed Hamdy, Jazia A. Alblowi, Dalia M. Ghalwash · 0 citations
Review Open access Aug 2026

Clinical and Esthetic Outcomes of Vestibular Socket Therapy: A Systematic Review and Meta-Analysis

Background/Objectives: Vestibular socket therapy (VST) is a minimally invasive technique for immediate implant placement (IIP) in compromised extraction sockets that reconstructs the deficient buccal plate while preserving the crestal soft tissue. Despite growing clinical adoption, the randomized evidence on its predic...

Y. Soliman, Nadine Gräfin von Krockow, Fatma E. A. Hassanein et al. · 0 citations
Open access Aug 2026

Monolithic Zirconia Versus Porcelain-Fused-to-Metal Implant-Supported Fixed Dental Prostheses in the Posterior Region: 3-Year Results of a Randomized Controlled Clinical Trial.

OBJECTIVES To compare the clinical, biological, and technical outcomes of posterior three-unit implant-supported fixed dental prostheses (iFDPs) fabricated from monolithic zirconia (MonoZR) or porcelain-fused-to-metal (PFM). MATERIALS AND METHODS In this prospective randomized controlled trial, partially edentulous p...

Aspasia Pachiou, Raphael Singh, Ronald E. Jung et al. · 0 citations
Review Open access Sep 2026

Comparative Efficacy of Bone Defect Filler Strategies Following Lesion Debridement for Osteonecrosis of the Femoral Head: A Systematic Review and Network Meta‐Analysis

ABSTRACT Objective This study aimed to systematically review and compare the clinical and radiographic outcomes of different bone defect filler materials following lesion debridement for osteonecrosis of the femoral head (ONFH). Existing evidence on filler materials relies heavily on isolated pairwise comparisons, leav...

Zu-Kang Miao, Zhi-Wei Pei, Bing Wang et al. · 0 citations
Aug 2026

The Effect of Osseodensification and Conventional Implant Site Preparation on Implant Stability of Tapered and Cylindrical Dental Implants: A Randomized Controlled Study.

Neither the choice of drilling technique nor the implant macrogeometry significantly influences insertion torque or stability levels in regions of low bone density in this randomized controlled clinical study.

Worood A Akram, S. Bede · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.