Skip to content
Open access

Mechanical and rheological behavior of robocast biphasic calcium phosphate cement reinforced with graphene nanoplatelets.

Aug 2026 · Journal of The Mechanical Behavior of Biomedical Materials · Vol 183, pp. 107603 · 0 citations · 40 references
Medicine

TL;DR

Graphene nanoplatelets (GNP) addition not only enhanced the mechanical strength but also improved the rheological behavior of BCPC pastes, resulting in better printability during the robocasting process, and all measured mechanical properties fell within the range reported for trabecular bone substitution applications.

Abstract

In this study, a biphasic calcium phosphate cement (BCPC) was fabricated, combining the biocompatibility of hydroxyapatite (HA) and the biodegradability of β-tricalcium phosphate (β-TCP), and processed by robocasting, an extrusion-based technique, for bone tissue engineering applications. Despite its well-known biological performance, this material is brittle - mainly used as bone graft substitutes due to its limited mechanical strength. To overcome this limitation, graphene nanoplatelets (GNPs) were incorporated into the cement as a reinforcing filler. Their addition not only enhanced the mechanical strength but also improved the rheological behavior of BCPC pastes, resulting in better printability during the robocasting process. In particular, the incorporation of GNPs reduced the elastic modulus of the pastes, facilitating extrusion. Bars with and without microporosity were 3D-printed and subsequently evaluated by flexural testing. The flexural strength of microporous BCPC samples increased from 4.2 MPa (0% GNP) to 5.9 MPa (2% GNP), representing a 40% improvement. Although dense samples also exhibited higher strength with GNP addition, the difference was not statistically significant. Distinct stress-strain curve profiles obtained during bending tests revealed the influence of the printed architecture on the mechanical response of the printed parts. The flexural modulus followed the opposite trend to the flexural strength, showing a significant increase in dense parts containing GNP, while no substantial change was observed in the microporous counterparts. Overall, all measured mechanical properties fell within the range reported for trabecular bone substitution applications.

Read PDF

Similar papers

Aug 2026

3D-Printed Poly(ε-Caprolactone)/CaCO3 Biocomposite Meshes for Bone Tissue Engineering: Enhanced Mechanical Strength and Cytocompatibility

Poly(ε-caprolactone) (PCL) is a biodegradable and biocompatible polyester widely used in biomedical scaffolds. However, its relatively low mechanical strength and limited cell adhesion properties remain major challenges for bone tissue engineering applications. This study developed a 3D-printed PCL mesh enhanced with...

Tanyaluck Mekpothi, Manasanan Namhongsa, Kittisak Yarungsee et al. · 0 citations
Aug 2026

Polylactic acid/hydroxyapatite composite filaments: Balancing printability, mechanical integrity, and osteogenic performance for bone tissue engineering.

Findings highlight the importance of controlling HAp loading to achieve a balanced combination of processability, structural integrity, and osteogenic performance in PLA-based biomaterials.

Lukošiūnas Jokūbas, Šaparajavaitė Gabrielė, Dambrauskas Tadas et al. · 0 citations
Sep 2026

Canabo microfiber and chitosan biopolymer reinforced with recycled PLA matrix using 3D printing technology for bone scaffold application. A characterization analysis

The results confirm that controlled chitosan loading plays a crucial role in tailoring the mechanical durability, degradation behaviour, and thermal stability of recycled PLA composites for advanced bone scaffold applications.

R. I, T. Jayakumar, Karpagarajan S et al. · 0 citations
Aug 2026

Multimaterial Synergy in Bioactive Polyetherketoneketone (PEKK) Composites for Advanced Skeletal Reconstruction

Polyetherketoneketone (PEKK) is a high‐performance thermoplastic polymer with bone‐mimetic mechanical properties and radiolucency, making it a promising alternative to conventional metallic orthopedic implants. However, its inherent bio‐inertness limits effective osseointegration and antibacterial performance. The pres...

Tapas Das, Debolina Saha, V. Balla et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.