Abstract Or004: Cardiac Hemodynamics in Extracorporeal Cardiopulmonary Resuscitation
Abstract
Introduction: Extracorporeal cardiopulmonary resuscitation (ECPR) with veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly being used to manage out-of-hospital cardiac arrest. However, significant debate remains regarding the hemodynamic effects of VA-ECMO. Research Questions: 1. What happens to cardiac hemodynamics upon VA-ECMO commencement in a large animal model of cardiogenic shock and cardiac arrest? 2. In humans that survive to a weaning study, how do invasive cardiac hemodynamics change when VA-ECMO flow is manipulated? Methods: We simultaneously conducted two prospective physiologic studies where we performed serial invasive hemodynamic and echocardiographic evaluations to define cardiac hemodynamics with VA-ECMO flow variations. The first study was a porcine study where we induced cardiogenic shock and cardiac arrest via coronary balloon occlusion and significant fluid loading in 60-65 kg Yorkshire pigs. The second study involved performing simultaneous left and right heart catheterization with three-dimensional echocardiography in humans cannulated for ECPR while sequentially weaning VA-ECMO flow. Serial hemodynamic comparisons were evaluated within each study using mixed effects models. Results: There were 15 animals in the porcine study (11 experimental and four controls) and 28 humans in the clinical study. In the animal study, VA-ECMO was commenced at a median of 2L/minute flow after cardiogenic shock and cardiac arrest were induced. The initiation of VA-ECMO led to reductions in left ventricular (LV) end-diastolic volume (p<0.001 for all stages of VA-ECMO support compared to measurements taken prior to cardiac arrest), LV end-diastolic pressure (p<0.001 for all stages), LV stroke work (p<0.05 for all stages), LV pressure-volume area (p<0.05 for all stages), and right atrial pressure (p<0.01 for all stages) (Figure 1). Mean pulmonary arterial pressure was not significantly different. In our clinical study, 28 humans completed the entire hemodynamic protocol at a median of 3.0 days after VA-ECMO cannulation. Reduction in VA-ECMO flow led to increases in LV end-diastolic pressure, end-diastolic volume, stroke work and pressure-volume area (Figure 2) as well as right atrial and mean pulmonary arterial pressures (all p<0.001 for lowest flow compared to baseline). Conclusions: Higher VA-ECMO flow reduces LV end-diastolic pressure, end-diastolic volume, and cardiac work both at the time of VA-ECMO commencement in an experimental model of cardiac arrest, but also in humans able to tolerate a weaning study.