Skip to content
Open access

Femoral artery diameter as an indicator of cardiopulmonary resuscitation quality: A secondary analysis of a porcine study

Jul 2026 · Hong Kong Journal of Emergency Medicine · Vol 33 · 1 citation · 21 references

TL;DR

Femoral artery diameter exhibited significant correlations with physiologic parameters, including DBP, CoPP, and CePP, and a larger diameter was associated with ROSC, and may serve as a reliable indicator of CPR quality.

Abstract

Femoral artery ultrasound has the potential to be utilized for hemodynamic monitoring during cardiopulmonary resuscitation (CPR). This study evaluated the correlation between femoral artery diameter and established physiologic parameters during CPR, as well as the association between femoral artery diameter and return of spontaneous circulation (ROSC). A secondary analysis of a porcine ventricular fibrillation cardiac arrest model was conducted. The primary exposure was femoral artery diameter measured via ultrasound every 2 minutes during cardiac arrest. Physiologic parameters including diastolic blood pressure (DBP), end‐tidal carbon dioxide (ETCO2), coronary perfusion pressure (CoPP), and cerebral perfusion pressure (CePP) were recorded throughout the experiment. The primary outcome was the mean difference in femoral artery diameter between pigs with and without ROSC, analyzed using a linear mixed model. Correlation coefficients were calculated using a mixed‐model approach. A total of 199 data points from 22 pigs were analyzed, with a median femoral artery diameter of 2.6 mm (interquartile range: 2.1–3.5). Femoral artery diameter was significantly larger in pigs with ROSC than in those without ROSC (mean difference [95% confidence interval (CI)]: 0.9 mm [0.3–1.4], p ‐value = 0.004). Although DBP significantly differed between ROSC and non‐ROSC groups, ETCO2 levels did not. Femoral artery diameter showed moderate correlations with DBP ( r  = 0.66 [95% CI: 0.56–0.75]), CoPP ( r  = 0.64 [95% CI: 0.52–0.76]), and CePP ( r  = 0.69 [95% CI: 0.60–0.77]). Femoral artery diameter exhibited significant correlations with physiologic parameters, including DBP, CoPP, and CePP, and a larger diameter was associated with ROSC. Given its ease of measurement with minimal CPR interruption, femoral artery diameter may serve as a reliable indicator of CPR quality.

Read PDF

Similar papers

Open access Aug 2026

Temporal Physiologic Profiles Associated with Return of Spontaneous Circulation in a Swine Model of Cardiopulmonary Resuscitation

Successful resuscitation was associated with a distinct pressure–flow–gas-exchange profile during early and pre-ROSC CPR, and these findings support further investigation of multimodal physiology-guided resuscitation.

B. Fyntanidou, E. Oloktsidou, Katerina Kotzampassi et al. · 0 citations
Aug 2026

Clinical utility of pulmonary artery catheter derived hemodynamic parameters: a prospective clinical study

Background. Induction of anesthesia and mechanical ventilation frequently lead to arterial hypotension whose nature can be elucidated through analysis of volumetric and pressure-derived hemodynamic parameters. These include measured or calculated, including indexed, indicators of the left and right cardiac chambers (le...

A. K. Kolotukhin, A. Bakanov, V. S. Shabaev et al. · 0 citations
Open access Oct 2026

Quantification of Ventricular Hydraulic Output Using Pressure/Flow Analysis: A Single-Animal Proof-of-Concept Study During Dobutamine Stress

Introduction: Ventricular pressure and arterial flow are commonly evaluated separately, although their instantaneous product represents hydraulic power. This study examined whether synchronized ventricular pressure and arterial flow recordings can be used to describe ventricular pressure/flow coupling and hydraulic out...

Filip Konecny · 0 citations
Sep 2026

Oxygen delivery during cardiopulmonary bypass and postoperative mortality: A retrospective cohort study.

BACKGROUND Oxygen delivery during cardiopulmonary bypass reflects the balance between pump flow, hemoglobin concentration, and arterial oxygenation and is a key determinant of tissue oxygen transport. While inadequate oxygen delivery has been linked to postoperative organ dysfunction, its association with mortality rem...

Mark J. Robitaille, Sebastian D. Sahli, L. Wachtendorf et al. · 0 citations
Aug 2026

End-diastolic velocity as a simplified bedside predictor of estimated cerebral perfusion pressure in neonates: A multicentre prospective observational study.

AIM To elucidate the relationship between estimated cerebral perfusion pressure and cerebral blood flow velocities or resistance index in neonates and to identify optimal Doppler cut-off values for predicting estimated cerebral perfusion pressure. METHODS This multicentre study included neonates with arterial lines a...

Masashi Zuiki, Mikito Ohta, Mariko Ishimaru et al. · 0 citations
Review Open access Aug 2026

Beyond Mean Arterial Pressure During Cardiopulmonary Bypass: Endothelial Reactivity, Oxygen Delivery, and Organ-Specific Perfusion.

Collectively, these investigations demonstrate that CPB-associated factors such as non-pulsatile flow and the kinetics of CPB initiation, early hypotension, hemodilution, hypothermia, systemic inflammation, oxidative stress, and anesthetic-induced vasodilation impair endothelial-mediated vascular responsiveness.

Ignazzo Condello, M. Dell'Aquila, S. Condello et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.