Skip to content

When Oracle Conditioning Misleads Deployment: Conditioning-Availability Bias in Echocardiographic Segmentation

Aug 2026 · 0 citations · 18 references
Computer Science

TL;DR

The complementary gap pair measures loss on the deployable oracle-estimated pathway and probes sensitivity on the oracle-random pathway to test whether oracle-conditioned performance survives the inference pathway actually available at deployment.

Abstract

Conditional segmentation models may be trained and evaluated with auxiliary signals cleaner than those available at deployment. We study this protocol-level manifestation of shortcut learning and auxiliary-variable shift in phase-conditioned echocardiographic segmentation. The complementary gap pair measures loss on the deployable oracle-estimated pathway and probes sensitivity on the oracle-random pathway. On held-out CAMUS data, one strong-cyclic, oracle-selected run fails severely with estimated phase, while sensitivity to incorrect phase persists across three runs. On EchoNet-Dynamic, the current estimator remains usable, but random-phase testing reveals strong latent sensitivity. Deployment-aware checkpoint selection and phase perturbation reduce both gaps with little change in mean Dice. Exploratory subgroup analyses quantify variation across measured strata, and a downstream ejection fraction (EF) audit shows that recovering segmentation does not necessarily recover EF error or signed bias. Together, the gaps test whether oracle-conditioned performance survives the inference pathway actually available at deployment.

View source

Similar papers

Preprint Aug 2026

Beyond Uncertainty: Generalizable Failure Monitoring for Surgical Segmentation under Acquisition Degradation

Surgical segmentation networks can fail silently under acquisition degradation: predicted masks may be wrong even when model confidence remains high. Existing deployment-time monitors rely primarily on uncertainty estimates and can therefore miss confident failures. We present TCSR-Monitor (Temporal Conformal Surgical...

Hieu D. Pham, D. Cao, T. Huynh · 0 citations
Preprint Aug 2026

CARD: Calibration via Agreement in Reverse Diffusion for Out-of-Domain MRI Segmentation

Across cardiac, prostate and brain MRI shifts, CARD lowers calibration error in 45 of 49 comparisons against the strongest baseline in each setting, and maps the temporal aggregate of this disagreement to a temperature field applied per pixel across all classes, so that confidence changes while the segmentation does no...

Jiateng Dai, Wei Guo, Qing-Biao Li et al. · 0 citations
Preprint Aug 2026

VIDS-Seg: Towards Reliable Uncertainty Quantification in Pediatric Cardiac Ultrasound Segmentation

VIDS-Seg is introduced, which applies amortized variational inference over a lightweight prediction head to make this adaptive, OOD-aware prior tractable for dense image segmentation, and indicates that OOD-aware uncertainty quantification can serve as a practical safety layer for deployed segmentation models.

Paul Fischer, Ece Ozkan · 0 citations
Preprint Sep 2026

From Few-Shot Segmentation to Clinician-in-the-Loop Medical Image Analysis

This work reframe FSMIS as a three-layer sequential decision problem, state six hypotheses with an explicit dependency order, and proposes a minimal pilot that can falsify the foundational self-assessment claim before a clinician study.

Ya-Zhou Zhu · 0 citations
#machine learning Preprint Sep 2026

Improving Calibration of Black-Box Radiology AI Using Test-Time Augmentation

Radiology AI systems increasingly inform clinical decisions such as triage, follow-up imaging, and treatment planning. For these decisions to be made safely, model outputs must be well calibrated, meaning predicted probabilities accurately reflect true risk. Many standard techniques for improving calibration, such as M...

Nathan Le, Magdalini Paschali, Arogya Koirala et al. · 0 citations
Preprint Sep 2026

When Online Adaptation Hurts: Parameter-Frozen Test-Time Ensembling for Continual Medical Image Segmentation

Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem without target labels, but it can be impossible to update a model on a non-stationary stream and can lead to a lot of errors. We examine a more reasonable and meaningfu...

Rui-Jie Huang · 0 citations

Related blog posts

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.