Cardiovascular 4D Flow MRI supports patient-specific hemodynamic assessment across complex cardiovascular conditions within a practical single-centre clinical workflow with retrospective quantification.
Abstract
Abstract Objectives To evaluate the feasibility and clinical utility of cardiovascular four-dimensional flow magnetic resonance imaging (4D Flow MRI) for multidirectional hemodynamic visualization and quantitative assessment. Methods This single-centre observational study included 30 cardiovascular MRI cases acquired at Huaqiao University Affiliated Strait Hospital using a Siemens MAGNETOM Skyra 3.0-T system with an 18-channel phased-array coil. Time-resolved three-dimensional velocity-encoded 4D Flow MRI was performed with retrospective electrocardiographic gating, respiratory compensation, and region-adjusted velocity encoding. Acquisition parameters included TR/TE 38.88/6.88 ms, flip angle 8°, matrix 256 × 256, field of view 300 mm, in-plane spatial resolution 1.4 × 1.4 mm, slice thickness 3 mm, and slice gap 0.6 mm. Preprocessing corrected background phase offsets, Maxwell terms, velocity aliasing, and noise artefacts. Results 4D Flow MRI enabled assessment of intracardiac shunting, pulmonary regurgitation, Fontan circulation, bicuspid aortic valve hemodynamics, aortic regurgitation, and atrioventricular valve dysfunction. Quantified parameters included pulmonary-to-systemic flow ratio, shunt volume, regurgitant fraction, peak velocity, pressure gradient, wall shear stress, vorticity, helicity, kinetic energy, turbulent kinetic energy, oscillatory shear index, and energy loss. Conclusions Cardiovascular 4D Flow MRI supports patient-specific hemodynamic assessment across complex cardiovascular conditions within a practical single-centre clinical workflow with retrospective quantification.
Volumetric real-time MRI is feasible for the guidance of invasive procedures such as right-heart catheterization at 0.55T and offers flexible real-time re-slicing, volumetric 3D visualization, and the potential for improved device monitoring.
Prakash Kumar, R. Ramasawmy, A. Javed et al.· Journal of Cardiovascular Ma...· 0 citations
Accelerated WH-4DF MRI is clinically robust and broadly applicable across CHD, including complex postoperative anatomies, and provides comparable numbers to 2D-PC, reproducible, and time-efficient flow quantification with superior coverage and reduced operator dependence.
J. van Schuppen, A. E. van der Hulst, R. Takx et al.· Journal of Cardiovascular Ma...· 0 citations
Silent MRA SI reflected 4D flow hemodynamics in non-FAs and DVs, but not in higher-velocity FAs, and Silent MRA-derived VBI showed potential for noninvasive hemorrhage risk stratification in BAVM.
Lin-Shu Yang, Xiaosheng Meng, Hai-Ning Wei et al.· Journal of Magnetic Resonanc...· 1 citation
A gradient-recalled echo (GRE) sequence is presented alongside an image-based analysis for SNR estimation and QC of 13C coils, advancing the clinical translation of 13C MRS methodologies.
Emil S Christensen, Andreas Clemmensen, E. S. Hansen et al.· Magnetic Resonance in Medici...· 0 citations
Although digital subtraction angiography remains the gold standard for the diagnosis and treatment planning of intracranial arteriovenous shunts (AVS), including arteriovenous malformations and arteriovenous fistulas, non-invasive imaging is increasingly sought for comprehensive evaluation. Magnetic resonance imaging (...
Akihiko Sakata, Koji Fujimoto, M. Iima et al.· Diagnostic and Interventiona...· 0 citations
Simultaneous structural-functional lung imaging in a single free-breathing acquisition was feasible in this cohort of older awake pediatric participants using 0.55-T MRI, with structural images suitable for evaluating major pulmonary findings and quantitative ventilation metrics correlating strongly with PREFUL.
Xin Miao, N. Lee, HaiThuy N. Nguyen et al.· Radiology advances· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.