Skip to content
Open access

Motion-Robust Approach for 4D Cardiac Cine Using 2D Real-Time Acquisitions and Slice-to-Volume Reconstruction.

Aug 2026 · Magnetic Resonance in Medicine · 0 citations · 46 references
Medicine

TL;DR

The RT-SVR approach enables 4D cardiac cine with comparable bi-ventricular volumes, contrast, sharpness, and acquisition time compared to standard breath-hold cine while providing additional motion robustness.

Abstract

Purpose

4D cardiac cine is a powerful tool for comprehensive cardiac function assessment; however, current methods rely on regular breathing and are sensitive to bulk motion and arrhythmia. We aim to develop a 4D cardiac cine approach that requires no patient cooperation and is robust to irregular breathing, bulk motion, and cardiac arrhythmia.

Methods

2D real-time (RT) spiral bSSFP with synchronized ECG was acquired in 4 cardiac orientations. In each orientation, the 2D slice was "swept" across the heart to provide volume coverage. Retrospectively gated slice-to-volume reconstruction (SVR) was then performed to reconstruct 4D cine with 1 mm3 voxel size and 25 cardiac phases. RT-SVR and clinical standard breath-hold short-axis cine were acquired in 19 subjects, including 4 arrhythmia and 2 myocardial infarction patients. Biventricular volumes were measured, and blood-myocardium contrast and boundary sharpness scores were compared.

Results

The RT-SVR approach successfully provided 4D cardiac cine for all subjects. Acquisition time was 8:33 ± 1:01 min and 8:27 ± 2:06 min (p = 0.85), blood-myocardium contrast ratio was 2.30 ± 0.58 and 2.38 ± 0.59 (p = 0.33), boundary sharpness was 1.11 ± 0.46 and 1.18 ± 0.53 (p = 0.04), for RT-SVR and breath-hold cine, respectively. Bi-ventricular volumes had good agreement, with an ejection fraction bias of -4.02% (p < 0.05) and -2.30% (p = 0.10) for left and right ventricles, respectively.

Conclusion

The RT-SVR approach enables 4D cardiac cine with comparable bi-ventricular volumes, contrast, sharpness, and acquisition time compared to standard breath-hold cine while providing additional motion robustness. This approach may be beneficial in patients that are non-cooperative, children, and those with irregular breathing and/or arrhythmia.

Read PDF

Similar papers

Preprint Aug 2026

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

The SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientat...

Arnaud Boutillon, Naomi Clarke, T. Woodgate et al. · 0 citations
Preprint Aug 2026

Coronary Mask Guided Registration for Continuous Time 4D Cardiac CT Dataset Construction

Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research....

Yuang Wang, Shuo Wang, Chang-Yu Chen et al. · 0 citations
Open access Sep 2026

Automated cardiac strain estimation from short-axis DENSE and Cine MR images

Cardiac strains provide significant information to evaluate cardiac performance. They can be evaluated using full field voxel-wise displacements measured, for example, using displacement encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI) or from features and textures that are measured using Cine M...

Mohammad Naqizadeh Jahromi, Rodrigo Menna Costa, Augusto Delavald Marques et al. · 0 citations
Open access Aug 2026

Accelerated Cardiac MRI Using Deep Learning Cine Imaging: Validation in Pediatric Patients both with and without Congenital Heart Disease.

BACKGROUND Conventional breath-held 2D bSSFP cine CMR requires multiple breath holds and prolonged acquisition time, posing challenges for children and patients with congenital heart disease (CHD). Deep-learning (DL)-based reconstruction enables undersampled data acquisition with rapid image completion, offering the po...

Jonathan Kochav, Jun-Jie Ma, S. Jambawalikar et al. · 0 citations
#diffusion models Preprint Aug 2026

Patch-Based Diffusion Reconstruction for Accelerated Cardiac Cine

Purpose: To develop and evaluate a diffusion-based reconstruction framework for highly accelerated 2D real-time (RT) cine cardiovascular magnetic resonance imaging (CMR). Methods: We trained an unconditional patch-based diffusion model and incorporated it into a reconstruction framework, termed CineDiff, using diffusio...

Xuan Lei, Philip Schniter, Juliet Varghese et al. · 0 citations
Open access Aug 2026

Volumetric real-time MRI for the guidance of cardiac catheterization at 0.55T.

Volumetric real-time MRI is feasible for the guidance of invasive procedures such as right-heart catheterization at 0.55T and offers flexible real-time re-slicing, volumetric 3D visualization, and the potential for improved device monitoring.

Prakash Kumar, R. Ramasawmy, A. Javed et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.