Skip to content
Open access

Long-term Performance of a Dynamic Clinical Decision Support System for Intravenous Insulin Therapy: A Retrospective Cohort Study in Patients With and Without Diabetes.

Jul 2026 · Journal of Diabetes Science and Technology · pp. 19322968261467050 · 0 citations · 33 references
Medicine

TL;DR

Use of Glucopilot, an electronic medical record-integrated adaptive insulin dosing software, was associated with timely attainment of euglycemia and sustained glycemic control with a median of 0% time in hypoglycemia in real-world practice.

Abstract

Objective

To report and analyze the long-term performance of Glucopilot, a clinical decision support system for intravenous (IV) insulin therapy.

Methods

This retrospective cohort study included adult patients across 9 hospitals who received IV insulin guided by Glucopilot between August 18, 2020 and May 30, 2025. Admissions with fewer than 10 hours of IV insulin or insufficient glucose monitoring were excluded. Using point-of-care glucose data from the electronic health record, we evaluated time to euglycemia, time in glycemic ranges, and severe dysglycemic events, with subgroup analyses (eg, diabetes type, diabetic ketoacidosis, sepsis, and steroid use) and multivariable models to assess glycemic performance and factors associated with sustained euglycemia (ie, 100% time in euglycemia after initial attainment) and severe hyperglycemia (ie, ≥300 mg/dL).

Results

There were 1239 admissions included. All patients presenting with hyperglycemia achieved euglycemia, with a median time to euglycemia of 174 minutes. Thereafter, median time in euglycemia was 96%, with 4% median time in hyperglycemia, and 0% median time in hypoglycemia. Sustained euglycemia was observed in 43.4% of admissions, and steroid use was not associated with reduced likelihood of achieving sustained euglycemia. Baseline glucose was strongly associated with time to euglycemia but not with subsequent time in euglycemia after attainment. Glycemic control was consistent across subgroups.

Conclusions

Use of Glucopilot, an electronic medical record-integrated adaptive insulin dosing software, was associated with timely attainment of euglycemia and sustained glycemic control with a median of 0% time in hypoglycemia in real-world practice.

Read PDF

Similar papers

Open access Oct 2026

Evaluation of continuous glucose monitoring outcomes and health care resource utilization in patients with non-insulin-treated type 2 diabetes.

BACKGROUND Although continuous glucose monitoring (CGM) is well established for insulin-treated diabetes, its utility in non-insulin-treated type 2 diabetes (T2D) remains less studied. OBJECTIVE To evaluate the short-term clinical and economic outcomes following personal use of CGM in patients with T2D. METHODS Thi...

S. Gadd, Connor W. Willis, Ishfaq Rashid et al. · 0 citations
Sep 2026

Continuous Glucose Monitoring and Hospitalization Outcomes in Adults with Insulin-Treated Type 2 Diabetes and Complex Care Needs: A Population-Based Study.

In this population-based cohort of adults with insulin-treated T2D and CCN, CGM initiation was associated with fewer hospitalizations, shorter hospital stays, and lower hospitalization costs, supporting the integration of diabetes technology into chronic care strategies for highly vulnerable populations.

Pablo Rodríguez de Vera Gómez, Á. M. Mesa Díaz, Eduardo Mayoral-Sánchez et al. · 0 citations
Open access Aug 2026

Association of continuous glucose monitoring with in-hospital adverse outcomes among critically ill patients: a real-world propensity score–matched study

Background Critically ill patients often experience substantial glycemic fluctuations, which are associated with adverse clinical outcomes. Conventional point-of-care glucose monitoring provides only intermittent measurements and may delay timely therapeutic adjustment. Continuous glucose monitoring (CGM) enables real-...

Ze-Yu Jiang, Ying-Ying Zhang, Zhen-Hui Dong et al. · 0 citations
Open access Aug 2026

Effect of early versus delayed or no insulin therapy for moderate hyperglycemia in ICU patients: A target trial emulation.

BACKGROUND Hyperglycemia is common in intensive care unit (ICU) patients and associated with increased mortality. Despite several randomized clinical trials within glucose management in critical illness, the effects of insulin treatment, and its timing, in patients with moderate hyperglycemia remain uncertain. RESEAR...

Christian Lange Gantzel, P. Yazdanfard, K. K. Sørensen et al. · 0 citations
Aug 2026

Continuous Glucose Monitoring and Automated Insulin Delivery in Infants with Type 1 Diabetes: Real-World Evidence to Support Future International Guidelines.

CGM is safe in very young children, with AID systems proving superior to traditional therapy, and real-world evidence supports incorporating AID consideration into future international guidelines from the time of pediatric diagnosis.

M. Marigliano, A. Scaramuzza, C. Arnaldi et al. · 0 citations
Open access Sep 2026

Impact of Hybrid Continuous Glucose Monitoring on Glycemic Control in a Medical Intensive Care Unit.

In this prospective MICU cohort, real-time hybrid CGM use improved glycemic control and reduced severe hyperglycemia without increasing hypoglycemia, supporting further evaluation of structured CGM integration in critical care practice.

E. Faulds, Melanie Natasha Rayan, Molly McNett et al. · 1 citation