Skip to content
Review

Cardiac Autonomic Neuropathy: Comparative performance of Phase-Rectified Signal Averaging methods with Cardiac Autonomic Reflex Tests and Time Domain Heart rate variability.

Mar 2026 · Nigerian Medical Journal · Vol 67, pp. 616 - 625 · 0 citations · 29 references
Medicine

TL;DR

This study compares PRSA methods with conventional methods and defines cut-off values for AC and DC to diagnose CAN and finds that a decrease in DC value and an increase in AC value are associated with a higher probability of CAN.

Abstract

Background: Phase-Rectified Signal Averaging (PRSA) methods, Deceleration (DC), and Acceleration Capacity (AC), provide a comprehensive assessment of cardiac autonomic function (CAN). There are no published studies comparing PRSA methods with conventional methods such as Time Domain Heart Rate Variability (TD-HRV) or Cardiac Autonomic Reflex Tests (CARTs), nor have they described a cut-off value for AC and DC to distinguish patients with CAN (+ve) from those without CAN (-ve). Our study compares PRSA methods with conventional methods and defines cut-off values for AC and DC to diagnose CAN. Methodology: We studied two cohorts: 126 individuals with normal ventricular function (derivation cohort) and 143 individuals with Left Ventricular Dysfunction (validation cohort). These patients underwent CARTs and supine, resting ECG recordings for 2 to 3 minutes. The patients were categorized as CAN +Ve and CAN -Ve based on TD-HRV parameters and the CARTs. Two different CART criteria were studied: the All-India Institute of Medical Sciences (AIIMS-AFT) criteria and the 2011 Toronto Consensus recommendations. Patients with and without CAN were segregated by AC and DC values, and the methods were compared. The cutoff values for DC and AC were calculated using the ROC curve method from the derivation cohort and verified in the validation cohort. Results: A reduction in DC values and an increase in AC values indicate a higher chance of CAN. The cut-off values of -7 for AC and 7 for DC provide the highest accuracy in detecting CAN prevalence. Both values have an AUC of nearly 0.9. Reclassifying both Cohorts as CAN +Ve based on the derived cut-offs and comparing with the prevalence determined by conventional methods results in kappa values ranging from 0.5 to 0.7. Conclusions: A decrease in DC value and an increase in AC value are associated with a higher probability of CAN. An AC value ≥ -7 and a DC value ≤ 7 indicate good accuracy in identifying CAN.

View source

Similar papers

Open access Aug 2026

Heart rate variability in Parkinson’s disease – A time domain analysis

Impaired autonomic function characterized by reduced parasympathetic modulation may occur in Parkinson’s disease according to time domain analysis of HRV.

Shamima Sultana, Mefhtahul Jannat, Esha Chowdhury et al. · 0 citations
Open access Aug 2026

Enhanced ECG signal based on heart rate variability: validation of the direct TR correction sequence in diabetes

The DTRC sequence significantly enhances HRV assessment accuracy, offering a reliable tool for early detection of autonomic dysfunction in high-risk populations and its simplified correction process and improved sensitivity hold promise for clinical diagnostics and wearable health monitoring applications.

Shanglin Yang, Hongbin Zhou, Xuwei Liao et al. · 0 citations
Aug 2026

Cardiovascular autonomic dysfunction in Morvan syndrome: A comparative study of heart rate variability and cardiovascular autonomic reflex tests.

Findings support the value of routine HRV and Ewing's battery assessment in Morvan syndrome for early detection of cardiovascular autonomic involvement and improved clinical monitoring.

Chandregowda Nandan, Ganagarajan Inbaraj, K. Arjun et al. · 0 citations
Sep 2026

Heart rate variability and baroreflex sensitivity derived from finger photoplethysmography during dynamic cerebral autoregulation assessments: Association with age, sex and time of day in healthy volunteers.

Purpose Assessing dynamic cerebral autoregulation (dCA) noninvasively includes continuous blood pressure recording with a photoplethysmography device. We investigated in this retrospective study whether, under these standardized laboratory conditions, the Finapress device can provide feasible measures of heart rate var...

M. Bolognese, Martin Müller, M. Österreich et al. · 0 citations
Open access Aug 2026

Heart rate variability, ECG minor changes, and HRV–ECG coupling associated with an adjunctive structured breathing–meditation protocol in combat-exposed military personnel

Given the non-randomized design, these findings warrant caution and support randomized trials, with HRV as an objective monitoring tool.

Viktor S Matsyshyn, A. Kravchenko, Nataliia M. Ovodiuk et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.