Findings support a risk-adapted approach to cardiac rhythm monitoring after ESUS, with patients with ESUS at markedly different risks of AFDAS identified as part of a risk-adapted diagnostic pathway for cardiac rhythm monitoring.
Abstract
Background: Atrial fibrillation detected after stroke (AFDAS) is frequently diagnosed after embolic stroke of undetermined source (ESUS) and has important implications for secondary stroke prevention. Although prediction scores have been proposed to identify patients at increased risk of AFDAS, prospective evidence supporting their implementation to guide rhythm monitoring in routine clinical practice is limited. Methods: In this prospective, population-based implementation cohort study, adults with ESUS were enrolled between January 2022 and December 2024 across all stroke centers in Styria, Austria. The Graz AF Risk Score was prospectively implemented as part of a risk-adapted diagnostic pathway for cardiac rhythm monitoring. Patients with a score [≥]4 were recommended for implantable loop recorder monitoring, whereas monitoring in those with scores <4 remained at the treating physician's discretion. The primary outcome was AFDAS detection; recurrent ischemic stroke and recurrent stroke etiology were secondary outcomes. Results: Among 784 patients (median age 73 years [IQR 64-80], 45.7% women), AFDAS was detected in 166 patients (21.2%) during a median follow-up of 26.3 months (IQR 20-34). AFDAS detection was substantially higher in patients with a Graz AF Risk Score [≥]4 than <4 (38.1% vs. 3.9%; p<0.001). After adjustment for age, sex and ILR monitoring, a score [≥]4 independently predicted AFDAS (HR 6.3, 95% CI 3.5-11.2; p<0.001) and recurrent ischemic stroke (HR 2.2, 95% CI 1.1-4.1; p=0.023). Only one recurrent stroke in patients with a score <4 was attributable to atrial fibrillation (AF) (1/18, 5.6%). Conclusions: Prospective implementation of the Graz AF Risk Score identified patients with ESUS at markedly different risks of AFDAS. A Graz AF Risk Score [≥]4 was also independently associated with recurrent ischemic stroke. These findings support a risk-adapted approach to cardiac rhythm monitoring after ESUS.
A PAVA score ≤ 2 demonstrates a high negative predictive value for AF/AT on ILR after cryptogenic stroke, offering a practical tool to optimize patient prioritization for ILR implantation.
In patients with cryptogenic stroke receiving an ICM, the ECG-AI score showed modest discrimination for AF detection, outperforming CHA2DS2-VA and HAVOC, but not Brown ESUS-AF, which indicates a possible role for AI-driven ECG analysis in risk stratification.
F. Wouters, M. Barthels, J. Vranken et al.· Digital Health· 0 citations
Abstract Aims Recurrence of symptomatic atrial fibrillation (AF) after catheter ablation (CA) is not uncommon. However, real-world long-term data on clinical outcomes of rhythm control strategies in patients with recurrent AF after CA remain limited. Methods and results Using the TriNetX database, we identified adult p...
Yong Hao Yeo, H. Wong, A. Vignarajah et al.· Europace· 0 citations
Extracranial clinically relevant bleeding is common among patients with AF treated with OACs and may more accurately reflect the overall burden of bleeding than major bleeding alone, suggesting that additional unmeasured or unknown factors contribute to bleeding risk.
Deborah M. Siegal, Marc Carrier, M. Bahit et al.· Circulation· 0 citations
Device-detected atrial high-rate episodes and subclinical atrial fibrillation occupy an intermediate state between an electronic signal and clinically documented atrial fibrillation. ARTESiA showed that apixaban reduced stroke or systemic embolism compared with aspirin while increasing major bleeding. NOAH-AFNET 6 foun...
Jordan Llerena-Velastegui, Ruth Jimbo-Sotomayor, J. Chávez et al.· Current problems in cardiolo...· 0 citations