Aug 2026· Diabetes Research and Clinical Practice· Vol 239, pp.
113470
· 0 citations· 23 references
Medicine
TL;DR
MiniMed™ 780G markedly improves glycemic control in people with LADA, supporting AHCLS as an effective therapeutic strategy in this population of insulin-treated patients with latent autoimmune diabetes in adults.
Abstract
Aims
To evaluate the effectiveness of the Medtronic MiniMed™ 780G Automated Hybrid Closed Loop System (AHCLS) in insulin-treated patients with latent autoimmune diabetes in adults (LADA).
Methods
Continuous glucose monitoring (CGM) data and clinical records were collected from individuals with LADA using the MiniMed™ 780G. Participants were BMI-matched with individuals with LADA treated with multiple daily injections (MDI) + CGM and with people with type 1 diabetes (T1D) using either AHCLS or MDI + CGM. Multivariable regression models adjusted for age, sex, and diabetes duration were used to assess the effect of AHCLS on CGM metrics. Differences in treatment effect between LADA and T1D were evaluated through an interaction analysis.
Results
AHCLS users showed higher time in range (TIR) than people on MDI (80 [71-87]% vs. 62 [50-75]%, p < 0.001) with no significant differences in the effect of AHCLS on TIR between people with LADA and T1D (p-interaction = 0.53). The percentages of patients meeting all CGM targets were 22.2% and 14.3% among people with LADA and T1D treated with MDI, and 54.4% and 77.8%, among those using AHCLS (p-value < 0.001; p-interaction = 0.39).
Conclusions
MiniMed™ 780G markedly improves glycemic control in people with LADA, supporting AHCLS as an effective therapeutic strategy in this population.
Although randomized controlled trials have demonstrated the efficacy of real-time continuous glucose monitoring (rtCGM), evidence from routine clinical practice remains limited, particularly in Asian populations. This study aimed to evaluate the effectiveness and safety of rtCGM initiation in individuals with diabetes....
Masao Toyoda, N. Sakane, A. Suganuma et al.· Endocrine journal· 0 citations
OBJECTIVES
While technology improves glycemic control, its psychological impact in resource-limited settings is less explored. This study evaluated the impact of continuous glucose monitoring (CGM) on diabetes distress and glycemic outcomes in adults with type 1 diabetes (T1D) within a public healthcare system.
METHO...
Nathalia Costa Monteiro, Laís Prado Smith Lima, J. P. A. Freitas et al.· Canadian Journal of Diabetes· 0 citations
BACKGROUND
A prior randomized trial showed that CGM lowers HbA1c in adults with type 2 diabetes and elevated glycated hemoglobin (HbA1c > 7.0%) not on insulin.
OBJECTIVES
We examined the effect modifiers of CGM effectiveness, and factors associated with HbA1c-lowering.
METHODS
Secondary analysis of data from a rand...
J. Zhang, Pratima Singh, Roseanne O. Yeung et al.· Canadian Journal of Diabetes· 0 citations
While the MiniMed™ 780G AID system use is associated with low CGM-derived hypoglycemia exposure and highly effective glycemic control, regardless of customized settings, superior glycemic control is associated with a higher proportion of user-initiated manual boluses.
Š. Volčanšek, P. Vidmar, A. Janež et al.· Frontiers in Endocrinology· 0 citations
Objective: This study aimed to evaluate how using personal health records (PHRs; Health2Sync®) impacts long-term glycemic management and body weight in people with type 2 diabetes (T2DM) and to identify factors associated with glycated hemoglobin (HbA1c) changes. Methods: This single-center, retrospective observational...
Isaki Hanamura, N. Abiru, Toshifumi Sakamoto et al.· Diabetology· 0 citations