Aug 2026· Journal of Clinical Medicine· Vol 15, pp. 6209· 0 citations· 36 references
Medicine
Abstract
Objectives: The purpose of this study was to evaluate the ability of computer vision models to detect myopia from standard colour fundus photographs and to compare their diagnostic performance with that of experienced ophthalmologists. Methods: A previously published dataset of 324 retinal fundus images labelled as myopic or non-myopic based on cycloplegic refraction as used for model training and internal validation. Images were acquired using a non-mydriatic 45° fundus camera. Final model evaluation was performed on an independent test set of 50 images from different patients who were not included in the original dataset. YOLOv8 and YOLOv11 variants were trained for binary classification. Internal validation used patient-level cluster bootstrap confidence intervals, whereas image-level bootstrap confidence intervals were estimated for the independent test set. Pairwise model comparisons were adjusted using the Holm–Bonferroni correction. Five experienced ophthalmologists independently classified the test set, and their consensus was compared with the selected YOLO models using DeLong’s and exact McNemar tests. Results: Internal validation identified YOLOv8-m and YOLOv11-n as the best-performing models according to a predefined composite score used exclusively for model selection. On the independent test set, YOLOv11-n achieved the highest area under the curve (AUC = 0.889), followed by YOLOv8-m (0.806), although the difference was not statistically significant (DeLong test, p > 0.05). The clinical consensus achieved an AUC of 0.832, with no significant difference compared with either model. Exact McNemar testing likewise revealed no statistically significant differences in paired classification outcomes between either AI model and the clinical consensus. Limitations include the small, single-centre, class- and age-imbalanced dataset and the limited number of expert observers. Conclusions: Although neither YOLOv8-m nor YOLOv11-n showed statistically significant differences from the clinical consensus on this independent test set, these findings should be interpreted cautiously given the relatively small, single-centre study population. Larger multicentre studies with independent external validation are warranted to confirm the generalisability, robustness, and potential role of clinician-driven computer vision models as decision support tools for myopia screening.
To develop and evaluate a deep-learning model for automated segmentation of myopic atrophic lesions on ultra-widefield (UWF) fundus images and to evaluate the effects of training-set size and color representation on segmentation performance.
This study included 500 UWF images from highly myopic eyes with m...
Hyunmin Na, Jun Sung Park, Seung-Woo Choi et al.· International Journal of Ret...· 0 citations
The offline AI-based non-mydriatic fundus camera showed high sensitivity and specificity for detecting referable diabetic retinopathy among participants with at least one gradable eye in a general outpatient setting in Liberia, and its feasibility for AI-assisted detection of referable DR in resource-limited settings i...
Vickie Fayiah Sam, M. Rizwan, J. C. Douglas et al.· Frontiers in Digital Health· 0 citations
BACKGROUND
Photoscreening can quickly detect amblyopia and strabismus, but there is little data on the performances of screening devices in low-income countries. The goal of this study was to assess the diagnostic accuracy of the Spot vision screener in Nepal.
METHODS
This prospective study enrolled a random sample o...
Manisha Shrestha, G. Bhandari, Sadhan Bhandari et al.· Journal of AAPOS· 0 citations
Background: Narrowing of the trabecular–iris angle (TIA) is a key anatomical feature of primary angle-closure disease and contributes to impaired aqueous humor outflow; however, conventional angle assessment requires specialized expertise or costly imaging equipment. This study aimed to develop an artificial intelligen...
Takahiro Mizukami, Jun Ohashi, Hiroki Nishimura et al.· Bioengineering· 0 citations
Background: Computer Vision Syndrome (CVS), also termed digital eye strain, is a constellation of ocular and visual symptoms associated with prolonged digital-screen exposure. The present study examined CVS in relation to Deha Prakriti and explored its symptom-based Ayurvedic correlation with Shushkakshipaka. Schirmer’...
Shukra Wankhade, R. Dhimdhime, Dipak Pandit et al.· Intemed International Journa...· 0 citations
TabPFN achieved the lowest mean absolute error (MAE) on all Eyerobo scenarios and was competitive with Ridge on auto-refractor scenarios; on the headline Eyerobo Pre + IOL scenario, the per-eye paired difference in MAE between TabPFN and the next-best gradient-boosting learner was 0.117 D in favour of TabPFN.
Meng-Meng Xia, Bo-Xue Yao, Yu-Mei Wang et al.· Ophthalmology and Therapy· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.