Interobserver Reproducibility of Ultrasound Measurement of Preperitoneal Fat Using a Convex Probe in the First Trimester of Pregnancy: A Prospective Study.

Jul 2026 · Journal of Clinical Ultrasound · 0 citations · 10 references
Medicine

TL;DR

Ultrasound-based measurement of preperitoneal fat thickness measurement using a convex probe is a highly reproducible and reliable technique across different observers and can be confidently implemented in routine clinical practice for the early identification of pregnant women at increased metabolic and obstetric risk.

Abstract

Objective

To assess the interobserver reproducibility of preperitoneal fat thickness measurement using a convex ultrasound probe in pregnant women at 12 weeks of gestation.

Methods

We conducted a prospective, cross-sectional observational study involving 50 women with singleton pregnancies between 11 + 5 and 12 + 6 weeks of gestation. Preperitoneal fat thickness was measured independently by three observers: one expert in obstetric ultrasound and two experienced obstetricians. Measurements were performed using a standardized protocol with a convex transducer at the midpoint between the xiphoid process and the umbilicus. Reproducibility was evaluated using the intraclass correlation coefficient (ICC) and Bland-Altman analysis.

Results

The technique demonstrated excellent interobserver reproducibility. The (ICC) were 0.985, 0.989, and 0.980 for pair comparisons observer 1-observer 2, observer 1-observer 3, and observer 2-observer 3, respectively. Mean difference ranged from -0.0063 to -0.0102 mm, suggesting minimal dispersion and no systematic bias.

Conclusion

Ultrasound-based measurement of preperitoneal fat using a convex probe is a highly reproducible and reliable technique across different observers. Given its noninvasive nature, accessibility, and excellent reproducibility, this method can be confidently implemented in routine clinical practice for the early identification of pregnant women at increased metabolic and obstetric risk.

View source

Similar papers

Open access Aug 2026

Reproducibility of Cervical Strain Elastography Using a Standardized Acquisition Protocol in Mid-Trimester Pregnancy.

Using a standardized acquisition protocol, strain elastography-derived EI demonstrates high intraobserver and interobserver reproducibility comparable to CL measurement, and its potential clinical applicability in mid-trimester cervical assessment is supported.

A. Benedeti, C. Coutinho, F. Mauad et al. · 0 citations
Open access Aug 2026

Population-based ultrasound reference values for inter-rectus distance: threshold prevalence, percentiles, and the limitations of fixed cutoffs

This population-based study aimed to characterize the distribution of inter-rectus distance (IRD) and its upper range in adult women using standardized multisite ultrasound measurements and a percentile-based interpretive framework. Data was driven from the Finnish Women’s Health Study (WENDY, 2020–2023), comprising wo...

Annu Marttila, Katariina Kilpivaara, J. Kinnunen et al. · 0 citations
Open access Sep 2026

Correlation Between Sonographically Measured Placental Thickness and Estimated Fetal Weight in Uncomplicated Singleton Pregnancies: An Observational Cross-Sectional Study

Background The placenta governs nutrient and oxygen transfer to the fetus, and its ultrasonographic thickness has been proposed as a simple, reproducible adjunct to conventional fetal biometry for assessing fetal growth. Evidence on the strength of this association, particularly across trimesters, remains variable acro...

Sameer, M. Aleem, Ekansh Rathoria et al. · 0 citations
Open access Sep 2026

Correlation between increased echogenicity of the fetal intestine on ultrasound and neonatal growth parameters: A retrospective study in a regional hospital of Taiwan.

OBJECTIVE To assess the association between fetal hyperechogenic bowel (FHB), detected through level II ultrasound, and early postnatal growth outcomes-birth weight, length, and head circumference-in a regional hospital in Taiwan. MATERIALS AND METHODS In this retrospective study, 158 neonates underwent prenatal leve...

Y. Huang, Kun-I Lin, An-Chyi Chen et al. · 0 citations
Open access Aug 2026

Reproducibility of ultrasound Doppler measurement of pulse wave velocity with different methods of assessing the superficial carotid-femoral distance

Aim . To calculate the reproducibility of the Doppler method for measuring carotid-femoral pulse wave velocity (cfPWV), taking into account various methods for establishing the surface distance between measurement points. Material and methods . Forty participants (men, 60%), aged 34,26±16,58 years, participate...

I. Posokhov, A. T. Betuganova · 1 citation
Open access Sep 2026

Point-Of-Care Ultrasound for the Assessment of the Cerebroplacental Ratio in Near-Term Pregnancies: An Agreement Study With Conventional Ultrasound.

OBJECTIVES The cerebroplacental ratio (CPR) is associated with perinatal mortality and morbidity, and its measurement has been proposed in uncomplicated pregnancies near term to identify fetuses at risk of adverse outcome. A major limitation to its widespread adoption is the lack of ultrasound equipment dedicated to an...

I. Mappa, Paola Metastasio, M. Derme et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.