This non-patient-specific CNN predicts static volumes and full 4D respiratory motion models from a single free-breathing scan, without a respiratory surrogate or projection binning, reducing motion artifacts while adding motion-modeling capability.
Abstract
Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts. We propose a deep learning method for motion-resolved 4D CBCT reconstruction from conventional free-breathing scans, without a respiratory signal or explicit projection binning. Our CNN takes free-breathing 3D CBCT projections as input and predicts a static volume at maximum inhalation plus ten displacement vector fields (DVFs) spanning a breathing cycle. The network extends U-Net: the encoder acts on filtered projection stacks, the decoder acts in the volume domain, and skip connections are replaced with non-trainable back-projection functions at multiple resolutions to transfer features between domains. The model is trained on simulated CBCT scans and evaluated on 11 unseen simulated patients and 13 clinical free-breathing scans. Two additional models (60 s and 6 s scans) were evaluated by clinical experts on three and two scans, comparing single phases of our 4D reconstruction to reference 3D SART-TV images for tumor and esophagus visibility. Experts preferred our method for tumor visibility (59% vs. 36% no preference, 5% reference) and esophagus visibility (47% vs. 42%, 11%). On simulated data, image quality matched SART-TV (mean RMSE: -1.19 HU, PSNR: +0.09 dB, SSIM: -0.009) while enabling 4D reconstruction. On clinical scans, our method showed sharper dynamic structures (e.g., diaphragm) and fewer motion streak artifacts than traditional reconstruction. This non-patient-specific CNN predicts static volumes and full 4D respiratory motion models from a single free-breathing scan, without a respiratory surrogate or projection binning, reducing motion artifacts while adding motion-modeling capability.
Low-Dose Computed Tomography (LDCT) reduces radiation exposure but introduces severe quantum noise and streak artifacts that degrade image quality. To address these challenges, we propose the Physics-Guided Sequential State Space Transformer (PS3T), a projection-domain denoising framework that combines sequential state...
Luella Marcos, Paul S. Babyn, Javad Alirezaie· Signals· 0 citations
Limited longitudinal field of view in cone-beam computed tomography (CBCT) remains a significant challenge for image-guided adaptive radiotherapy. We developed a deep learning-based CBCT outpainting framework that synthesizes anatomically consistent extensions beyond the scanned volume. The model employs a dual-branch...
Soyoung Chung, J. Kim, Min-Gyo Chung et al.· Journal of imaging informati...· 0 citations
CAMIT provides an effective trade-off between 2D efficiency and 3D contextual modeling, supporting treatment-day anatomical assessment and adaptive workflow guidance, and is evaluated on an unpaired pelvic CBCT/CT dataset.
Xu Chen, Yun-Kui Pang, J. Lian et al.· Biomedical engineering and p...· 0 citations
BACKGROUND
Respiratory motion and inter-fraction anatomical variations reduce the accuracy of dose delivery in lung cancer radiotherapy. Projection-based tumor tracking methods are limited by anatomical overlap and weak tumor contrast. This study developed a deep learning-based real-time, angle-agnostic tumor tracking...
Qiu-Yi Ye, Xiang-Yu Zhang, Xiang-Jie Tan et al.· Physica medica (Testo stampa...· 0 citations
TLCE-morph, a Tri-Path Lie Convolution Encoder-based learning framework for deformable respiratory motion correction in thoracic PET, achieves the most favorable overall quantitative performance and shows more consistent local structural recovery in representative motion-sensitive regions.
Hui Zhou, Long-Xi He, Si-Yu Wang et al.· Frontiers of Physics· 0 citations
Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have sho...
Jia-Le Shen, Guo-Lin Wang, Chen-Hao Wang et al.· 0 citations