Evaluated across four IEEE test systems under in-region attacks blocking up to 20% of measurements, AdaptoNet recovers F1 from below 12\% to above 81\%, an approximate sevenfold improvement approaching the 89%-99% baseline with complete measurements.
Abstract
Cyber attacks on the power grid combine physical disruptions with compromised data to destabilize cyber-physical systems. We demonstrate that data denial attacks, where adversaries block measurements in a targeted region while triggering a line outage, reduce detection performance by more than 86\%, rendering standard data-driven methods ineffective. We propose AdaptoNet, a modular neural network that adapts to measurement availability through conditional controls. AdaptoNet pairs a frozen foundational module trained on complete data with a trainable adaptive module, conditioned on a binary measurement-availability vector, enabling the model to distinguish between denied and anomalous data without retraining the foundational module. Evaluated across four IEEE test systems (30-, 39-, 57-, and 118-bus) under in-region attacks blocking up to 20% of measurements, AdaptoNet recovers F1 from below 12\% to above 81\%, an approximate sevenfold improvement approaching the 89%-99% baseline with complete measurements.
Wide-area monitoring, protection, and control (WAMPAC) systems damp inter-area oscillations in large interconnected grids, but their reliance on synchronized PMU measurements carried over wide-area networks exposes them to false data injection (FDI) attacks. This paper presents an attack-resiliency analytics framework...
Mohammad Zakaria Haider, Prabin Mali, N. Haque et al.· 0 citations
The high rate of transformation of traditional power grids into smart grids has facilitated enhanced monitoring, control, and automation, however, it has also provided a wide cyber-physical attack frontier. The False Data Injection Attacks (FDIAs) are among the most challenging cyber threats, because they can tamper wi...
S. Rani, Mathilde Arnaud· International Symposium on N...· 0 citations
Power grid state estimation relies on sensor measurements that are increasingly vulnerable to adversarial corruption in cyberphysical environments, potentially leading to significant deviations in system observations. This motivates the need to identify critical measurement nodes whose compromise results in the most se...
Simulation results indicate that the proposed framework improves attack detection accuracy, reduces economic losses, and enhances system resilience relative to conventional deterministic protection approaches.
A train network control system is a cyber–physical system (CPS) whose safe operation depends on the integrity and timeliness of on-board sensor data. As such systems migrate towards networked and wireless architectures, the measurement link becomes exposed to replay, denial-of-service (DoS) and false data injection att...