Aug 2026· Frontiers in Cardiovascular Medicine· Vol 13· 0 citations· 18 references
Medicine
TL;DR
Patient-specific computational simulation of TEVAR was associated with postprocedural hemodynamic profiles that closely matched simulated predictions, and showed favorable periprocedural trends and potential utility in optimizing pre-TEVAR planning.
Abstract
Background The accuracy and clinical utility of patient-specific computational simulations for thoracic endovascular aortic repair (TEVAR) planning in Stanford type B aortic dissection (TBAD) patients remain insufficiently validated. Objectives This study aimed to develop and validate the safety and efficacy of a patient-specific computational simulation framework tailored for TEVAR in patients with TBAD. Methods This prospective, observational, multicenter study enrolled 153 consecutive patients with TBAD undergoing TEVAR. Patients were stratified into two groups: the simulation group (n=72) and non-simulation group (n=81). For the simulation cohort, personalized three-dimensional models of the stent frame and covered graft were constructed based on preprocedural computed tomography angiography, followed by computational simulation. The predictive performance of the simulation was evaluated by comparing simulated hemodynamic parameters with postprocedural measurements. The primary endpoint was the procedural success rate. Results The overall cohort had an average age of 67.1 ± 9.1 years, with 66.0% being male. The simulation group showed a higher procedural success rate (100.0% vs. 95.1%, P = 0.042), lower rates of endoleak (0% vs. 9.9%, P = 0.007) and stent-related rupture (0% vs. 4.9%, P = 0.002), and a lower complete false lumen thrombosis rate (61.1% vs. 79.0%, P = 0.015) compared to the non-simulation group. Notably, postprocedural hemodynamic metrics (including maximum pressure gradient, peak velocity, and wall shear stress) were significantly improved in the simulation group (all P < 0.001). Conclusions Patient-specific computational simulation of TEVAR was associated with postprocedural hemodynamic profiles that closely matched simulated predictions, and showed favorable periprocedural trends and potential utility in optimizing pre-TEVAR planning. These findings are preliminary and require validation in randomized controlled settings.
Although transcatheter aortic valve implantation (TAVI) has been demonstrated to be a successful treatment for aortic stenosis, it remains associated with complications, such as paravalvular leakage (PVL). To address these, TAVI devices continue to undergo iterative development. Integration of in silico trials into the...
S. Verstraeten, Marloes van Driel, Robin Willems et al.· Biomechanics and Modeling in...· 0 citations
Background: Thoracic endovascular aortic repair (TEVAR) is increasingly considered in selected patients with uncomplicated type B aortic dissection (uTBAD), but uncertainty remains regarding indications for intervention and treatment strategies. This study aimed to explore potential variation in TEVAR indications and t...
Bianca Biersteker, Felix Hers, Meike Langenhuijzen et al.· Journal of Clinical Medicine· 0 citations
INTRODUCTION
Endovascular aortic repair (ENDO) in connective tissue disease (CTD) patients has historically been discouraged in societal guidelines because of durability concerns. However, high-volume aortic centers increasingly employ ENDO strategies in carefully selected high-risk scenarios such as rupture, dissectio...
Walker R. Ueland, Pavel Mazirka, Michael J. Fassler et al.· Journal of Vascular Surgery· 0 citations
Component quantification of EL demonstrated preliminary feasibility for evaluating Type I endoleak in patients with EVAR for AAA, demonstrating greater advantages over WSS-related hemodynamic parameters.
Ran Tao, Qi-Ming Liu, Weihao Guo et al.· Frontiers in Cardiovascular...· 0 citations