Skip to content
Open access

Feasibility and short-term outcomes of bioadaptor in bifurcation intervention using culotte technique: intravascular ultrasound analysis from a single-center experience

Jul 2026 · Journal of Cardiovascular Imaging · Vol 34 · 0 citations · 42 references
Medicine

TL;DR

Early experience with bioadaptor implantation in culotte bifurcation stenting in culotte bifurcation stenting demonstrates feasibility, with favorable acute IVUS findings in selected patients.

Abstract

The DynamX bioadaptor is a novel coronary implant with three helical strands that unlock and separate to provide dynamic vessel support restoring natural vessel function. Evidence in complex bifurcation lesions requiring planned two-stent strategies is limited. This analysis evaluated the feasibility and short-term outcomes of culotte bioadaptor implantation using intravascular ultrasound (IVUS). Thirteen consecutive patients underwent bifurcation percutaneous coronary intervention using culotte technique with DynamX bioadaptor between February and October 2025. All procedures followed a standardized culotte protocol with lesion preparation, proximal optimization technique, rewiring, and final kissing balloon inflation, with IVUS used to assess bioadaptor expansion, apposition, and structural integrity. Technical and procedural success was achieved in all patients (100%), with successful rewiring through bioadaptor struts in all attempts (26 of 26, 100%). IVUS demonstrated satisfactory expansion: main branch ostial expansion 94.9% ± 10.6%, side branch ostial expansion 90.2% ± 17.5%, and proximal expansion ratio 0.95 ± 0.16. No strut fractures or malapposition occurred. Early experience with bioadaptor implantation in culotte bifurcation stenting demonstrates feasibility, with favorable acute IVUS findings in selected patients.

Read PDF

Similar papers

Open access Sep 2026

Comparison of short-term myocardial perfusion and clinical outcomes between balloon stent kissing technique and junctional wire technique strategies in true bifurcation lesions of the left anterior descending artery and diagonal branch

Objectives: To compare the clinical efficacy of the Balloon Stent Kissing Technique (BSKT) and Junctional Wire Technique (JWT) for treating true bifurcation lesions of the coronary left anterior descending artery (LAD) and diagonal branch. Methodology: A retrospective analysis included data from 235 patients who underw...

K. Ren, Hong-Yu Wang, Xi-Ming Li · 0 citations
Open access Aug 2026

The ATTAIN Technique (Amplatz lefT guiding caTheter pArtIal deploymeNt): An Alternative Approach for Transradial Stenting of Low-Origin Vertebral Artery Ostial Stenosis.

The ATTAIN technique showed preliminary feasibility and provided a standardized AL guiding catheter-assisted deployment sequence for selected right-sided low-origin VAOS, and provided a standardized AL guiding-catheter-assisted deployment sequence for selected right-sided low-origin VAOS.

Han-Ming Ge, Xiao-Bo Zhang, Zhan-Hua Liang et al. · 0 citations
Open access Aug 2026

Pulsatile Intravascular Lithotripsy for Heavily Calcified Femoropopliteal Arterial Disease: First-in-Human Results from the POWER PAD I Feasibility Study

Background/Objectives: Severe arterial calcification remains a major challenge during femoropopliteal endovascular intervention, limiting luminal gain and increasing the risk of vessel-wall injury, restenosis, and bailout stenting. Pulsatile intravascular lithotripsy (PIVL) is a novel calcium-modification technology th...

B. Mwipatayi, Bernardette Jingfei Lee, Davina Daudu et al. · 0 citations
Open access Sep 2026

Position-Dependent Hemodynamics of Popliteal Artery Stent Grafts: The POPFLEX Study

Background: Endovascular exclusion of popliteal artery aneurysms (PAAs) with long covered stent-grafts is valuable for patients unfit for open surgery but is undermined by late stent thrombosis, even in fully scaffolded segments without kinking, a failure best clarified by computational fluid dynamics (CFD), which requ...

Christos Chronis, K. Tzirakis, N. Kontopodis et al. · 0 citations
Open access Sep 2026

Treating Calcified Above- and Below-the-Knee Arteries with a Focused Force PTA Balloon: Results from the UltraScore Post-Market, Real-World Study

Objective: To assess the clinical use of the UltraScore balloon in a real-world setting. Methods: This is a prospective, multicenter, single-arm, real-world study to assess the clinical use of the UltraScore balloon for the treatment of stenotic lesions of the superficial femoral artery (SFA), popliteal and below-the-k...

Craig Walker, Robert E. Beasley, Kuldeep Singh et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.