Jul 2026· IEEE Jordan Conference on Applied Electrical Engineering and Computing Technologies· pp. 423-428· 0 citations· 13 references
Abstract
The reconstruction of volumetric computed tomography (CT) from two orthogonal X-ray projections is an inverse problem that is difficult to solve as only limited depth information can be obtained from the two-dimensional (2D) projections of three dimensional (3D) anatomies. The majority of previous work has concentrated on improving the reconstruction model, whereas the goal of this work is to improve the input representation before the 3D reconstruction stage, we introduce a diagnostic benchmarking framework to obtain intermediate pseudo-volumetric diagnostic inputs before CT prediction from the digitally reconstructed radiographs (DRRs) in both anterior-posterior (AP) and lateral (LAT) views. This validates the pipeline by experimentation: CT-to-CT; simplified DRR-to-CT and Plastimatch-based DRR-to-CT. Then, it tests one-channel, three-channel and five-channel pseudo-volumetric representations on top of a 3D U-Net-based reconstruction backbone. The peak signal-to-noise ratio (PSNR) and three-dimensional structural similarity index measure (SSIM3D) were used to quantify the evaluation. For multi-patient experiments, enriching the pseudo-volumetric representation was found to yield better validation PSNR from 17.24 dB with pseudol to 18.55 dB with pseudo5, and a mean PSNR of 19.27 dB during validation inference. The results demonstrate that input representation quality and projection consistency are two important factors for biplanar X-ray-to-CT reconstruction. The proposed framework is thus designed as a way to analyze input representations and is not a clinically deployable CT replacement system.
Ultra-sparse cone-beam computed tomography (CBCT) reconstruction is important for low-dose and rapid 3D imaging, including C-arm-assisted interventions, yet the Feldkamp-Davis-Kress (FDK) algorithm and simultaneous iterative reconstruction technique (SIRT) degrade under sparse views. We propose a cross-domain framewo...
Bo-Dong Bi, Bo Yang, Zhi-Xin Liu et al.· Measurement and control (Lon...· 0 citations
PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images, demonstrates that it surpasses existing plug-and-play diffusion and fully trained reconstruction approa...
Wei-Cheng Dai, Shantanu Ghosh, K. Batmanghelich· Lecture notes in computer sc...· 0 citations
LiftXR is proposed, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction, and consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art.
Yi-Fei Wu, Yi-Cheng Wu, Qiang Ma et al.· 0 citations
A Multi-Pass Multi-View Blended Learning framework for synthesizing high-fidelity volumetric CT directly from real chest X-ray (CXR) images that mitigates the synthetic-to-real domain gap while enhancing both the structural integrity and anatomical detail of the final output.
Ozer Can Devecioglu, S. Kiranyaz, Rashid Mazhar et al.· 0 citations
A three-stage framework that consists of an implicit neural representation (INR) for estimating missing parts of the truncated projection data, an iterative reconstruction for generating a secondary volumetric image with improved anatomical consistency and a fast diffusion model for image enhancement is proposed.
Susanne Schaub, Florentin Bieder, Matheus L. Oliveira et al.· 0 citations
This paper proposes an interpolation method that effectively interpolates secondary scans from limited observations that is based on a continuous mathematical model describing the secondary sinogram only with information from the projection space.
Yue-Jie Liu, Alessandro Lupoli, D. Gallo et al.· 0 citations