Skip to content
Open access

Evaluation of AI‐based segmentation and synthetic CT generation for MRI‐only prostate radiotherapy planning

Aug 2026 · Journal of Applied Clinical Medical Physics · Vol 27 · 0 citations · 25 references
Medicine

TL;DR

Evaluating whether an MRI‐only workflow, using commercial AI models for segmentation and sCT generation (MVision), demonstrates performance comparable to expert‐defined segmentations and reference CT‐based calculations within the studied dataset confirms that an AI‐segmentation and MRI‐sCT workflow provides geometric, image, and dose accuracy comparable to manual‐ and CT‐based references, supporting their integration into clinical workflows for pelvic radiotherapy.

Abstract

Abstract Background There is an increasing use of magnetic resonance imaging (MRI) for segmentation of target volumes and organs at risk due to superior soft tissue contrast compared to computed tomography (CT). Conventional workflows require CT‐MRI registration, introducing geometric uncertainty that can propagate to dose delivery. MRI‐only radiotherapy, based on AI‐generated synthetic CT (sCT) and segmentations from T2‐weighted images, offers a single‐modality approach, potentially eliminating registration errors. Purpose Our study aims to evaluate whether an MRI‐only workflow, using commercial AI models for segmentation and sCT generation (MVision), demonstrates performance comparable to expert‐defined segmentations and reference CT‐based calculations within the studied dataset. Methods We analyzed five segmentations on 19 male pelvis patients from the Gold Atlas dataset, providing deformably co‐registered CT and MRI, sCTs, with multi‐observer and consensus segmentations. We investigated segmentation accuracy, image similarity, and evaluated the dosimetric impact by comparing AI‐ to manual segmentations and CTs to sCTs. Wilcoxon signed‐rank tests were used for statistical significance and leave‐one‐out kappa determined segmentation outliers. Results Results show that AI‐segmentations achieved accuracy comparable to interobserver variability across all organs. Median Dice coefficients exceeded 0.9 for the prostate and bladder, and distance metrics closely matched the manual results. The leave‐one‐out kappa showed that AI‐segmentations were indistinguishable from manual observers for all organs. sCTs showed high similarity to the reference CTs, with a median mean absolute error of 34.0 HU and median structural similarity index of 0.93. Dose recalculations showed excellent agreement; median 3D‐gamma pass rate was 99.8% (2%/2 mm), and mean absolute dose difference was 0.036 Gy. All evaluated clinical dose constraints remained fulfilled after recalculation on the sCT. Conclusions Our results confirm that an AI‐segmentation and MRI‐sCT workflow provides geometric, image, and dose accuracy comparable to manual‐ and CT‐based references, supporting their integration into clinical workflows for pelvic radiotherapy.

Read PDF

Similar papers

Open access Aug 2026

How bone mis‐segmentation affects MRI‐based sCT dosimetry in head and neck radiotherapy: A CT‐referenced study

Abstract Background Magnetic resonance imaging (MRI) is commonly used for head‐and‐neck (H&N) delineation in radiotherapy (RT) owing to the lack of contrast in computed tomography (CT) images. MRI‐based dosimetry is not yet fully developed for the H&N area due to the inter‐patient variability and the difficulty of accu...

Laura Sayaque, Nils Tanneau, Charlène Bouyer et al. · 0 citations
Open access 2026

Comparative Analysis of AI Architectures for Prostate Gland Segmentation on MRI

Prostate gland segmentation on magnetic resonance imaging (MRI) is important for prostate cancer treatment planning, but manual segmentation is time-consuming and subject to inter-reader variability. Deep learning models may offer automation and efficiency, but boundary uncertainty, tissue heterogeneity, morphological...

Ryan Karim, Sumedh Sonawane, R. Shiradkar · 0 citations
Open access Sep 2026

Application of synthetic computed tomography based on a deep learning model in pelvic radiotherapy planning: A feasibility study

Abstract Background While computed tomography (CT) remains an important imaging modality in radiotherapy planning, magnetic resonance imaging (MRI)‐only workflow, often realized via the generation of synthetic computed tomography (sCT), is desired due to superior soft‐tissue contrast and less susceptibility to registra...

Feng-Nian Lin, Jin-Yan Hu, Zhao-Zhe Li et al. · 0 citations
Open access Sep 2026

Comparative evaluation of VoxelMorpand conventional deformable image registration algorithms for thoracic 4D‐CT in radiotherapy

Abstract Background Deformable image registration (DIR) is essential for thoracic four‐dimensional computed tomography (4D‐CT)‐based radiotherapy applications. Recently, deep learning‐based DIR methods such as VoxelMorph have been proposed; however, their performance relative to clinically used DIR algorithms remains u...

Mizuha Sakai, M. Nakao, H. Hirashima et al. · 0 citations
Open access Sep 2026

Contour‐regulated registration framework for Liver CT perfusion images

Liver computed tomography perfusion (CTp) imaging enables quantitative assessment of vascular dynamics but is highly susceptible to motion‐induced artifacts arising from breath‐hold variability and involuntary patient motion. These effects cause different portions of the liver to fall within the imaging field of view a...

Zhan Xu, Yao Zhao, Xin-Ru Chen et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.