Jul 2026· Indian Journal of Science and Technology· Vol 19, pp. 1717-1728· 0 citations
Abstract
Objectives: Irregular buildings are highly prone to torsional effects and excessive lateral deformations during earthquakes due to the non-uniform distribution of mass and stiffness. Although in Reinforced Cement Concrete (RCC) frame steel bracing systems and shear walls are widely used to enhance seismic performance, comprehensive comparative studies involving multiple bracing configurations and shear walls with identical location and orientation in irregular Steel–Concrete Composite (SCC) buildings remain limited. This study evaluates the effectiveness of different seismic resistance techniques in improving the seismic behaviour of an irregular SCC building. Method: A G+15 storey L-shaped SCC building was modelled and analysed in ETABS 22.0. For the same SCC structure five steel bracings Diagonal, Inverted V, V, K and X bracing and Reinforced Concrete (RC) shear walls were incorporated at identical locations. Response Spectrum Analysis (RSA) was performed in accordance with IS 1893(Part 1):2016. Seismic performance was assessed using storey displacement, storey drift, storey stiffness, fundamental time period and torsional irregularity ratio. Findings: The integration of seismic resistance techniques significantly improved the seismic performance of the irregular composite building. Among the bracing systems, X-bracing showed the best performance by reducing storey displacement, storey drift and fundamental time period by 56.06%, 60.42% and 37.88%, respectively. Inverted V-bracing provided the highest storey stiffness, whereas K-bracing achieved the lowest torsional irregularity ratio. The shear wall system showed best overall improvement, reducing displacement, drift, fundamental time period and torsional irregularity ratio by 70.29%, 76.52%, 51.63% and 40.87%, respectively, while achieving the highest storey stiffness. Novelty: Unlike previous studies focused on RCC and regular buildings or individual strengthening systems, the present study provides a comprehensive comparison of SCC structure with five steel bracing configurations and RC shear walls placed at identical locations under identical modelling, loading and seismic conditions to identify the most effective seismic resistance strategy.
Keywords: Steel-Concrete Composite structure, Plan Irregularity, Steel Bracing, Shear Wall, Response Spectrum Analysis
Seismic retrofitting of existing reinforced concrete (RC) buildings is often required because of deficiencies in their original design, changes in seismic provisions, or increased functional demands. This study evaluates the effectiveness of steel bracing for improving the seismic performance of a ten-story, plan-irreg...
H. Jarrahi, Abbas Sadeghi, S. Vaziri· Research on Engineering Stru...· 0 citations
This study investigates the seismic performance of multi-storey reinforced concrete (RC) buildings integrated with RC shear walls, using ETABS software for structural modelling and dynamic analysis. Building models with G+3, G+13, and G+23 storeys were analysed in accordance with IS 1893:2016 provisions, representing s...
E. Ganesh, K. Archana, Nayakanti Rajeev et al.· International Journal of Lat...· 0 citations
The seismic design of multi‐story steel buildings requires balancing structural efficiency, drift control, and material economy. This study presents a parametric comparison of moment‐resisting steel and steel‐concrete composite buildings, where steel beams interact with concrete slabs through shear connectors. Numerica...
Carlos Quishpe Otacoma, Natividad García-Troncoso, Guillermo Muñoz et al.· ce/papers· 0 citations
Reinforced concrete (RC) framed buildings with masonry infill are widely used in earthquake-prone regions; however, variations in the distribution of masonry infill and the presence of vertical irregularities can significantly alter their seismic behaviour. Although masonry infill walls are generally considered non-str...
Abhay Sharma, M. Khan· International Journal of Cre...· 0 citations
The seismic performance of dissipative timber structures is strongly influenced by the elastic‐fragile behavior of the material and the dissipation capacity is generally concentrated in steel connections, as indicated in the current seismic standards for timber structures. However, the connections should be preserved t...
Steel plate shear walls (SPSWs) have been increasingly recognised as an efficient and cost‐effective system for resisting lateral loads in medium‐ and high‐rise buildings. SPSWs rely on the post‐buckling tension field action of the infill plate to resist lateral loads. Although this mechanism enables significant energy...
I. Curkovic, D. Skejić, Ivan Lukačević· ce/papers· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.