Skip to content
#software testing Review Open access

From Respiratory Instability to Operational Monitoring: A Deterministic Phase-Memory Framework for Chest-Mounted Wearables

Sep 2026 · Smart Wearable Technology · 0 citations · 30 references
Non-Invasive Vital Sign Monitoring

TL;DR

A translational validation architecture focused on high-exertion terrestrial training and occupational or first-responder heat-and-PPE tasks is added and defines a falsifiable pathway toward fit-for-purpose evaluation without claiming clinical validation, military qualification, spaceflight readiness, or deployment-level safety.

Abstract

Chest-mounted inertial sensing offers a low-cost route to continuous respiratory-pattern monitoring, but operational use is constrained by motion artifacts, baseline drift, nonspecific physiological interpretation, and the risk of treating an unvalidated deviation score as a diagnostic or readiness decision. This structured narrative review and methodological framework builds on a published proof-of-concept deterministic phase-memory operator for chest-mounted smartphone inertial measurement unit (IMU) signals. The present manuscript adds a translational validation architecture focused on high-exertion terrestrial training and occupational or first-responder heat-and-PPE tasks. It specifies signal-quality and artifact-rejection gates, a guarded dual-timescale baseline that limits absorption of progressive deterioration, pre-specified verification and validation endpoints, reference instrumentation, and governance requirements for privacy, autonomy, human oversight, and prohibition of unsupported automated command or employment decisions. Phase-memory divergence is retained as an auditable deviation observable rather than a disease classifier. A valid alert requires acceptable signal quality, no artifact-gate condition, threshold exceedance, and temporal persistence; otherwise, the required output is indeterminate/low quality. Real-time human-in-the-loop alerts and post-session trend analysis remain separate outputs. Proposed quantitative criteria are engineering targets for future preregistered studies, not achieved performance claims. The framework therefore defines a falsifiable pathway toward fit-for-purpose evaluation without claiming clinical validation, military qualification, spaceflight readiness, or deployment-level safety. Received: 13 May 2026 | Revised: 27 July 2026 | Accepted: 21 August 2026 Conflicts of Interest The author declares that he has no conflicts of interest to this work. Data Availability Statement No new empirical dataset was generated or analyzed for this framework article. The public repository at https://github.com/dfeen87/Smartphone-Based-Chest-Monitoring contains the reference implementation and reproducibility materials for the previously published respiratory proof-of-concept article, including documented parameters, tests, validation scripts, dependency files, and a one-command reproduction workflow. The repository does not constitute clinical or operational validation of the broader architecture, baseline safeguards, proposed go/no-go targets, or future application contexts described here. Any prospective confirmatory analysis must cite and archive the exact release/commit and configuration manifest used. Author Contribution Statement Marcel Krüger: Conceptualization, Methodology, Software, Validation, Formal analysis, Investigation, Resources, Data curation, Writing – original draft, Writing – review & editing, Visualization, Supervision, Project administration.

Read PDF

Similar papers

Open access 2026

Heartbeat Signal Imputation in Doppler Radar Using Bidirectional Long Short-Term Memory for Random Body Movement Mitigation

Continuous heart rate (HR) monitoring is vital for early diagnosis and the prevention of patient deterioration. Although clinical gold-standard methods, such as electrocardiography (ECG), offer high accuracy, their contact-dependent nature causes discomfort and restricts mobility during prolonged observation. Non-conta...

Nadiya Azka, Rachmad Setiawan, T. Sardjono et al. · 0 citations
Open access Sep 2026

DuBCG: Unlocking In-Home, Clinically Comparable mmWave Cardiac Monitoring for Co-Sleepers via Physics-Informed Spatial Sensing

Continuous, fine-grained cardiac monitoring during sleep is vital for cardiovascular health. Emerging as a promising alternative to cumbersome wearables, mmWave radar offers a contactless, privacy-preserving modality capable of capturing minute skin vibrations. However, transitioning mmWave radar from labs to real-worl...

Xu-Sheng Zhang, Duo Zhang, Jing-Fu Dong et al. · 1 citation
Review Open access Sep 2026

From wrist to heart: clinical validation and real-world translation of wearable and portable AI-enhanced electrocardiography

Abstract Wearable and portable electrocardiogram (ECG) devices are shifting cardiovascular monitoring beyond clinician-directed testing, driven by consumer-led self-monitoring, remote care, and preventive cardiology. Artificial intelligence (AI) may enhance the value of these devices by supporting automated interpretat...

A. El-Medany, A. Birdi, Aron Abraham et al. · 0 citations
Open access 2026

Interpretable Reliability Control for Wearable PPG Heart Rate Estimation

Wearable photoplethysmography (PPG) can return a plausible heart rate (HR) after motion or poor optical coupling has made the measurement unreliable. We treat HR reporting as a reliability-control problem and introduce an interpretable signal quality index (SQI) layer that reports coverage and residual error. On PPG-Da...

Ye-Kun Liang, Shi-Wei Zhang, Zhou Yang · 0 citations
Book Open access Oct 2026

WearICG: Towards A Wearable Approach to Continuous Stroke Volume Monitoring

Wearable devices have made continuous monitoring of basic vitals such as Heart Rate (HR), Heart Rate Variability (HRV), oxygen saturation (SpO2), single-lead electrocardiogram (ECG) routine, but the advanced hemodynamic markers needed to anticipate cardiovascular events remain confined to the clinic. Stroke Volume (SV)...

Vignesh Ravichandran, A. Balaji, Andrea Ferlini et al. · 0 citations
Open access Sep 2026

From signal to construct evidence: multimodal consumer-wearable sensing in real general-aviation flight

We asked how far multimodal consumer-wearable signals recorded during real general-aviation flight can be treated as construct-relevant measurement rather than as records of motion, posture, or task structure. Forty pilots flew five standardized maneuvers in a Cessna 172 while frontal electroencephalography (EEG and AF...

Rong-Bing Xu, Shi Cao, Michael Barnett-Cowan et al. · 0 citations

Related blog posts

GPT-Lab Nov 3, 2026

Sovereignty Is the Option to Leave

Is your company’s AI sovereign? A practical guide for CIOs on AI vendor lock-in, EU Data Act switching, cloud sovereignty, and testing your exit plan before you need it. The post Sovereignty Is the Option to Leave appeared first on GPT-Lab.

Microsoft Research Blog Oct 30, 2026

From synthetic enterprise data evaluations to real Microsoft Copilot AI confidence

Evaluating Microsoft Copilot at enterprise scale requires test data that captures the full complexity of real organizations, yet real enterprise data contains sensitive information that cannot be used for evaluation under any circumstances. The post From synthetic enterprise data evaluations to real Microsoft Copilot AI confidence appeared first on Microsoft Research.

Microsoft Research Blog Oct 29, 2026

Microsoft Research Focus – Edition #97

Host Sowbhagya Suresh shares some of the latest news and cutting-edge research from across Microsoft—from understanding the challenges facing coding agents to uncovering how people use AI at work and improving extended-range weather forecasting. The post Microsoft Research Focus – Edition #97 appeared first on Microsoft Research.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.