Skip to content
Open access

Noise‐Level Adaptive Diffusion Priors for Zero‐Shot Low‐Field MRI Quality Enhancement

Aug 2026 · NMR in Biomedicine · Vol 39 · 0 citations · 41 references
Medicine

TL;DR

The proposed method (Nila) improved visual image quality, noise suppression, and tissue contrast, while preserving lesion‐region appearance in patient cases, and suggests that high‐field diffusion priors can serve as practical and reusable tools for LF‐MRI enhancement across heterogeneous systems.

Abstract

Low‐field MRI (LF‐MRI) improves imaging accessibility, but its practical utility is often limited by reduced signal‐to‐noise ratio, weaker tissue contrast, and variable image quality. These challenges are further compounded by the limited availability of low‐field training data across scanners and the fact that raw k‐space data are not always accessible in research and clinical workflows. In this study, we adapted a high‐field‐trained diffusion model for LF‐MRI quality enhancement without low‐field retraining or fine‐tuning. During inference, the pretrained diffusion prior was combined with noise‐level adaptive measurement guidance to suppress low‐field noise while maintaining consistency with measurement‐supported anatomical structures. With phase augmentation, this framework was further extended to magnitude‐only DICOM‐exported inputs when measured phase information was unavailable. The method was evaluated on 10 locally recruited healthy volunteers scanned at 0.05, 0.3, and 3 T, a public 0.064‐T healthy‐subject dataset with 10 paired cases, and patient cases acquired at 0.05 and 0.35 T. Compared with raw LF input and representative baselines including BM3D, MiDiffusion, and NAFNet, the proposed method (Nila) improved visual image quality, noise suppression, and tissue contrast, while preserving lesion‐region appearance in patient cases. On the 0.3 and 0.064 T datasets with coregistered 3‐T references, Nila achieved the best LPIPS and the highest or tied‐highest NMI across contrasts, indicating improved similarity to the high‐field reference. Multisample posterior inference further produced uncertainty maps that provide an explainable‐AI view of spatial output variability, with elevated variance mainly localized to tissue boundaries and ambiguous regions. These results suggest that high‐field diffusion priors can serve as practical and reusable tools for LF‐MRI enhancement across heterogeneous systems.

Read PDF

Similar papers

Open access Sep 2026

Empirical noise mapping guides optimal region‐of‐interest selection for accurate noise estimation in prostate DWI

Abstract Background Signal‐to‐noise ratio (SNR) measurements are important for quality assurance, especially when quantitative MRI markers or new hardware are being developed or evaluated. Regions of low signal or assumed uniform signal are used for SNR estimation in a variety of MR image types, but this is unreliable...

Milica Medved, Aritrick Chatterjee, Ambereen Yousuf et al. · 0 citations
Open access Aug 2026

Phantom evaluation of small‐pixel effect in ultra‐high‐resolution photon‐counting CT: Noise texture and high‐contrast spatial resolution

Abstract Background Ultra‐high‐resolution (UHR) photon‐counting CT (PCCT) with small‐pixel detectors improves resolution and noise, but its dependence on diverse imaging conditions remains insufficiently characterized. Purpose To systematically evaluate the small‐pixel effect in UHR PCCT by assessing noise properties a...

Kyu-Ho Song, C. Shan, G. Xu et al. · 1 citation
Preprint Sep 2026

Physics-informed denoising method for image reconstruction in quantitative low-field MRI

The proposed modular unrolled end-to-end deep learning method and its underlying method offer an efficient and flexible solution to denoise low-field MR data and make quantitative low-field MRI a feasible diagnostic tool for clinical applications.

Catarina Redshaw Kranich, C. Prieto, Christoph Kolbitsch et al. · 0 citations
2026

Measurement-Consistent Low-Field MRI Enhancement via k-Space Noise Modeling

Low-field magnetic resonance imaging (MRI) has gained increasing attention as a cost-effective and portable alternative to high-field MRI, particularly in resource-limited conditions. However, its inherently low magnetic field strength leads to reduced signal intensity and a low signal-to-noise ratio (SNR), resulting i...

Yutao Hu, Qi Liu, Tao Zhou et al. · 1 citation
Open access Aug 2026

Null-Space Diffusion Restoration With Adaptive Uncertainty-Guided Fusion for Ultrasound Speckle Reduction

An uncertainty-guided null-space diffusion (UGNS) framework is proposed, a novel label-free solution that enforces consistency correction on a stabilized positive-envelope proxy obtained via inverse log compression and achieves competitive generalized contrast-to-noise ratio values across diverse datasets.

June-Young Lee, Jae Choi · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.