A physics-driven iterative framework rooted in the polychromatic Polyquant attenuation model is proposed, which decouples scatter and beam hardening artifacts by establishing an optimization loop between scatter estimation and relative electron density (RED) reconstruction.
Abstract
Cone-beam computed tomography (CBCT) is fundamentally challenged by scatter and beam hardening artifacts, which originate from X-ray scattering and the polychromatic nature of the X-ray spectrum, respectively. These two types of artifacts are intricately coupled in reconstructed images and manifest with similar streaking and cupping features, severely compromising high-precision CBCT imaging. This paper proposes a physics-driven iterative framework rooted in the polychromatic Polyquant attenuation model, which decouples these artifacts by establishing an optimization loop between scatter estimation and relative electron density (RED) reconstruction. We develop a hybrid strategy for scatter estimation, in which the first-order scattering component is analytically derived based on a polychromatic physical model to preserve high-frequency structural information, whereas the smoother multiple scattering component is efficiently estimated via an object-adaptive convolution module. Subsequently, for beam-hardening correction, we introduce a voxel-adaptive update mechanism that solves linearized, scatter-corrected polychromatic equations to derive optimal weights, enabling direct RED refinement without manual parameter tuning. The proposed method was validated through comprehensive studies on biomedical phantoms, utilizing both Monte Carlo simulations and physical experiments. Representative results demonstrate that the proposed method outperforms state-of-the-art techniques, with the mean relative error decreased from 11.96\% to 1.27\% for the anthropomorphic head phantom and from 12.55\% to 5.46\% for the physical Yin-Yang phantom.
X-ray computed tomography (CT) is an essential imaging technology in clinical diagnosis. However, scattered photons can reduce image contrast and introduce CT value bias, which severely degrades image quality. Recently, scatter correction methods based on the Boltzmann transport equation (BTE) have attracted increasing...
BACKGROUND
The constrained one-step spectral CT image reconstruction algorithm (cOSSCIR) is a model-based approach that iteratively estimates basis material maps directly from a set of transmission measurements. By incorporating a model of the imaging system's x-ray beam and detector response, the method can be applied...
B. Rizzo, E. Sidky, Taly Gilat Schmidt· Medical Physics (Lancaster)· 0 citations
Objective. Gamma Knife cone-beam computed tomography (CBCT) images are deteriorated by cone-beam artifacts whose magnitude increases along the superior direction. In this study, a novel scan trajectory compatible with the Gamma Knife CBCT system is optimized to reduce cone-beam artifacts, with the aim to replace the cu...
Alexandra Alain-Beaudoin, H. Nordström, Luc Beaulieu et al.· 1 citation· ⚡1
Spectral computed tomography (CT) extends conventional CT by measuring attenuation across multiple energy channels, allowing improved modeling of physical X-ray interactions and energy-dependent material behavior and leading to richer scene understanding. We present a novel method for spectral CT reconstruction and bas...
Reinout Vos, Saptarshi Neil Sinha, M. Weinmann· 1 citation
High-density metallic objects often produce missing or severely corrupted projection data, resulting in strong streak artifacts in x-ray computed tomography (CT) images. In this paper, we propose a path-length-aware sinogram completion framework that combines interpolation in the mean attenuation domain with direct enf...
J. Seo, Sungwhan Kim· Biomedical engineering and p...· 0 citations
Coherent diffractive imaging (CDI) reconstructs object complex amplitudes from diffraction patterns using iterative phase retrieval algorithms, while multi-wavelength CDI (MW-CDI) improves reconstruction robustness through wavelength diversity. However, practical MW-CDI systems remain affected by probe-object coupling,...
Zhi-Peng Li, Suhas P. Veetil, A. Sun et al.· Journal of Optics· 0 citations