Skip to content
Open access

Localized Quadratic RF Encoded Spin‐Echo With Spiral‐PRIME Reconstruction: A Practical Alternative to 3D FSE for High‐Resolution Volumetric Brain MRI

Aug 2026 · Magnetic Resonance in Medicine · Vol 96, pp. 2615 - 2628 · 0 citations · 22 references
Medicine

Abstract

To extend localized quadratic (LQ) RF encoded spin‐echo imaging with acquisition and reconstruction strategies that improve efficiency and artifact robustness, positioning it as a practical alternative to 3D FSE for high‐resolution volumetric brain MRI.

Read PDF

Similar papers

Aug 2026

Evaluation of k‐Space Acquisition Strategies in Nonuniform B0 (NuBo) MRI

To evaluate k‐space acquisition strategies for magnetic resonance imaging (MRI) in a nonuniform B0 (NuBo) field‐cycling system, focusing on image quality, scan‐time efficiency, robustness to B0 inhomogeneity, and RF coil bandwidth constraints.

Y. Ha, Chenhao Sun, Anja Samardzija et al. · 0 citations
Open access Sep 2026

Feasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla

Perfusion MRI, especially dynamic susceptibility contrast (DSC), is vital for glioma diagnosis and monitoring. While gradient‐echo DSC is the current recommended implementation, combined spin‐ and gradient‐echo (SAGE) DSC additionally allows for vessel size imaging (VSI) and has shown feasibility for microvascular char...

Karen N. van der Werff, D. van Dorth, Krishnapriya Venugopal et al. · 0 citations
Open access Aug 2026

Incomplete Spoiling Correction for 3D T1 Mapping

Assess the impact of incomplete spoiling and spatial saturation on T1$$ {T}_1 $$ mapping using the variable flip angle (VFA) spoiled gradient recalled echo sequence (SPGR). Develop a correction for incomplete spoiling that results in an accurate estimate of T1$$ {T}_1 $$ , essential for quantitative MRI applications.

Gabriela Belsley, Damian J. Tyler, Matthew D Robson et al. · 0 citations
Open access Aug 2026

Multi‐Vendor and Multi‐Site Characterization of 13C Coils for Clinical Studies

A gradient-recalled echo (GRE) sequence is presented alongside an image-based analysis for SNR estimation and QC of 13C coils, advancing the clinical translation of 13C MRS methodologies.

Emil S Christensen, Andreas Clemmensen, E. S. Hansen et al. · 0 citations
Open access Oct 2026

Frequency-domain Based Optimization of Voxel Networks for Non-invasive Magneto-anatomical Mapping

Abstract Cardiac arrhythmias are one of the world’s leading causes of death. Non-invasive magneto-anatomical mapping aims to identify arrhythmogenic regions based on external magnetic sensors. An alternating two-stage state estimation and parameter optimization scheme has proven promising for cardiac current density es...

Lukas Elsner, H. Eikens, Sören Lange et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.