Aug 2026· Magnetic Resonance in Medicine· Vol 96, pp. 2615 - 2628· 0 citations· 22 references
Medicine
Abstract
To extend localized quadratic (LQ) RF encoded spin‐echo imaging with acquisition and reconstruction strategies that improve efficiency and artifact robustness, positioning it as a practical alternative to 3D FSE for high‐resolution volumetric brain MRI.
To evaluate k‐space acquisition strategies for magnetic resonance imaging (MRI) in a nonuniform B0 (NuBo) field‐cycling system, focusing on image quality, scan‐time efficiency, robustness to B0 inhomogeneity, and RF coil bandwidth constraints.
Y. Ha, Chenhao Sun, Anja Samardzija et al.· Magnetic Resonance in Medici...· 0 citations
Perfusion MRI, especially dynamic susceptibility contrast (DSC), is vital for glioma diagnosis and monitoring. While gradient‐echo DSC is the current recommended implementation, combined spin‐ and gradient‐echo (SAGE) DSC additionally allows for vessel size imaging (VSI) and has shown feasibility for microvascular char...
Karen N. van der Werff, D. van Dorth, Krishnapriya Venugopal et al.· NMR in Biomedicine· 0 citations
Assess the impact of incomplete spoiling and spatial saturation on T1$$ {T}_1 $$ mapping using the variable flip angle (VFA) spoiled gradient recalled echo sequence (SPGR). Develop a correction for incomplete spoiling that results in an accurate estimate of T1$$ {T}_1 $$ , essential for quantitative MRI applications.
Gabriela Belsley, Damian J. Tyler, Matthew D Robson et al.· Magnetic Resonance in Medici...· 0 citations
A gradient-recalled echo (GRE) sequence is presented alongside an image-based analysis for SNR estimation and QC of 13C coils, advancing the clinical translation of 13C MRS methodologies.
Emil S Christensen, Andreas Clemmensen, E. S. Hansen et al.· Magnetic Resonance in Medici...· 0 citations
To adapt and validate a linear binning technique, developed for hyper‐polarized 129Xe MRI, for functional lung MRI with matrix‐pencil decomposition (MP)‐MRI.
M. Curdy, Carmen Streibel, Oliver Bieri et al.· Magnetic Resonance in Medici...· 0 citations
Abstract Cardiac arrhythmias are one of the world’s leading causes of death. Non-invasive magneto-anatomical mapping aims to identify arrhythmogenic regions based on external magnetic sensors. An alternating two-stage state estimation and parameter optimization scheme has proven promising for cardiac current density es...
Lukas Elsner, H. Eikens, Sören Lange et al.· Current Directions in Biomed...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.