The accuracy of reverse scan body technique for capturing full-arch digital implant impressions: An in vitro study.

Sep 2026 · Journal of Prosthodontics · 0 citations · 28 references
Medicine

TL;DR

The RSB technique was inferior to the desktop scan in terms of digital impression and definitive prostheses accuracy, however, the RSB technique produced zirconia prostheses within the clinically acceptable deviation value of 0.15 mm.

Abstract

Purpose

This study assessed the accuracy of full-arch implant prostheses milled using a reverse scan body (RSB) impression technique compared to those generated from a digitized master cast using a desktop scanner.

Materials And Methods

A mandibular All-on-4 master cast was created and digitized using a reference desktop scanner. For each RSB scan (Group 1), an interim milled polymethylmethacrylate (PMMA) prosthesis was picked up from the cast, RSBs were hand-tightened, and captured using an intraoral scanner (IOS). For Group 2, abutment-level scan bodies were hand-tightened into the multiunit abutments (MUAs) of the master cast and scanned using a desktop scanner. The deviation between each resultant scan from each group was digitally compared to the MUAs position of the digitized master cast. The digital deviation and clinical passivity (modified one screw and screw resistance tests) between the milled zirconia prosthesis from each group were compared to the master cast.

Results

The deviation of the RSB-IOS impression (median = 0.07 mm) was statistically significant (p = 0.015) when compared to the desktop scan impression (median = 0.05 mm). For the milled zirconia prostheses, a similar statistically significant difference was observed with corresponding deviation values of 0.15 ± 0.02 and 0.11 ± 0.01 mm for the RSB and the desktop scanner groups, respectively. The passivity of the zirconia prostheses on the master cast showed variability when judged by three outcome assessors.

Conclusion

The RSB technique was inferior to the desktop scan in terms of digital impression and definitive prostheses accuracy. However, the RSB technique produced zirconia prostheses within the clinically acceptable deviation value of 0.15 mm.

View source

Similar papers

#software testing Open access Sep 2026

Influence of arch form on the accuracy of digital workflow in all-on-four implant rehabilitation cases (an in vitro study)

Variations in arch form may influence the accuracy of digital impressions for implant-retained fixed dental prostheses. Differences in arch width, curvature, and span length can affect scanning continuity and data stitching, potentially impacting trueness and precision during full-arch acquisition. However, the extent...

M. S. Torky, Rewaa G. AboElhassan, Amir S. Azer · 0 citations
Open access Sep 2026

Accuracy and clinical passive fit of reverse and standard scan body protocols for complete-arch implant-supported digital impressions: An in vitro study.

PURPOSE The purpose of this in vitro study was to compare the reverse scan body (RSB) and standard scan body (SCB) protocols for complete-arch implant-supported digital impressions with respect to root mean square (RMS), linear deviation, and angular deviation values, as well as clinical passive fit. MATERIALS AND ME...

Rabia Kilicaslan Dasdelen, İkbal Leblebicioğlu Kurtuluş, K. Kılıç · 0 citations
#software testing Open access Sep 2026

Accuracy of Direct Intraoral Versus Reverse Scanning for Abutment-Level Implant Impressions: an In Vitro Study

Abstract Objective The aim of the study was to compare the relative accuracy of direct intraoral scanning and reverse scanning techniques (RST) for abutment-level implant impressions, with specific evaluation of putty-only impressions and alginate casts. Materials and methods An in vitro study was conducted using a 3D-...

Sumit Deshpande, Diksha Rajkumar Kasnale, Konark N. Patil et al. · 0 citations
Open access Sep 2026

Model-free digital-correction workflow for multi-implant restorations: A clinical proof-of-concept study.

PURPOSE This clinical proof-of-concept study evaluates the feasibility and accuracy of a digital workflow for fabricating and correcting implant-supported restorations of multiple dental implants in an edentulous maxilla using intraoral scanning and reverse-scan bodies. METHODS An intraoral scan (IOS) was performed u...

A. Kernen-Gintaute, M. Akulauskas, F. Kernen et al. · 0 citations
Sep 2026

Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans.

STATEMENT OF PROBLEM The accuracy of implant scans may be influenced by the intraoral scanner (IOS) system and the intraoral scan body (ISB) materials. However, evidence regarding their impact remains limited. PURPOSE The purpose of this in vitro study was to evaluate the trueness and precision of 3-unit implant scan...

Bahar Gurpinar, Burcu Kanat-Ertürk, Mehmet Karakuzu et al. · 0 citations
Open access 2026

Trueness and Precision of Three Intraoral Scanners for Full-Arch Digital Impressions Exported in PLY Format: An In Vitro Study

Background: To evaluate the accuracy and precision of digital dental impressions using the Polygon File Format (PLY) across three intraoral scanners. Methods: A maxillary arch resin model with reference points was scanned 10 times using the intraoral scanners (3Shape TRIOS 5, Medit i900, Cameo Elegant 3) and a laborato...

Saud J. Dizayee · 0 citations