Skip to content

Author

Koyar Afrasyab

2 papers indexed here

We haven’t gathered this author’s papers yet. Follow them and we’ll fetch their work.

Not the right person? Other researchers publish under this name.

Preprint Jul 2026

Evaluating medical AI under missing information: same-provider judges and human raters change apparent safety

Readiness stress-testing of medical AI has focused on closed-ended and multimodal benchmarks. We extend it to open-ended clinical conversation under missing information, where safe behavior means recognizing absent information and qualifying, clarifying, or not over-committing - and where the evaluator becomes part of the measurement. We stress-test four models - three flagships (Claude Opus 4.8, GPT-5.5, Grok 4.3) and one mid-tier model (Gemini 3.5 Flash) - by deleting the latter half of the final user turn in HealthBench conversations, grading responses with a four-provider LLM-judge panel and a blinded clinician-anchored reference. Two evaluator-facing results are robust. First, judge choice materially changes apparent safety: inter-judge agreement is only moderate (Fleiss'kappa = 0.65), and after adjusting for each judge's general leniency (vote-level logistic regression), a positive same-provider association remains (exact permutation p = 0.04; GPT-5.5 ~ +0.10 on the probability scale) - large enough to change which model appears to over-commit least once its own-provider judge is excluded. Second, LLM judges are more permissive than clinicians on a blinded 50-item subsample: all four are significantly more lenient than the stricter independent clinician (crediting appropriate uncertainty on 66-84% of items vs 52%), and three of four than the author-influenced consensus (Grok directional only; judge-vs-consensus kappa = 0.20-0.43). On the author-audited clinical-underdetermined subset the permissiveness gap widened and the point-estimate model ordering held. A closed-ended MedQA anchor confirms accuracy is high and option-order effects are within a +/-5-point equivalence region for three of four models, so the safety gap is about calibration, not knowledge. We release the harness, prompts, per-item outputs, judge panel, perturbation audit, and human-annotation protocol.

Koyar Afrasyab · 0 citations
Review Jul 2026

Judge-dependent safety gains and model-specific helpfulness costs of evidence-sufficiency prompting in clinical LLMs

Background: LLM judges increasingly score whether clinical language models give overconfident answers under incomplete evidence, yet whether a measured"safety gain"reflects real behavior change or the judge's calibration is unresolved. Using a structured evidence-sufficiency prompt as a test case, we asked whether it reduces unsafe overconfident answers, how far that effect depends on the scoring judge, and what it costs in helpfulness. Methods: In a retrospective public-data benchmark (Real-POCQi, HealthBench, MedRBench), four models (GPT-5.5, Claude Opus 4.8, Gemini 3.5 Flash, Grok 4.3) answered a fully paired common panel (1,200 cells) with a standard prompt and the wrapper. The pre-specified endpoint was the paired reduction in unsafe overconfidence scored by the primary judge (GPT-5.4-nano); secondary analyses added a different-family judge (Claude Sonnet 5), a correctness judge, matched scaffold controls, and a blinded three-clinician review. Results: Unsafe overconfidence fell from 49.3% to 24.7%, a paired reduction of 24.7 points (95% CI 21.8-27.7; p<0.001), robust in direction across models and paraphrases. Magnitude was judge-dependent: Sonnet agreed on direction but nearly halved the effect (+13.1 points), with one-directional disagreement. Blinded clinicians characterized the primary judge as a high-sensitivity (1.00), low-specificity (0.55) screen, not a calibrated rate. The gain carried a model-specific helpfulness cost (correct diagnosis 80.3% to 50.3%): near-free for GPT-5.5, near-total for Gemini (-58 points). Matched scaffold controls showed genuine behavior change, not judge circularity. Conclusions: LLM-judged clinical safety effects should be reported as directional and relative, anchored to human review and evaluated jointly with helpfulness, not as calibrated absolute rates. This does not establish clinical deployment readiness.

Koyar Afrasyab · 0 citations